Air Ease Furnace Manual

The Air Ease Furnace is a high-efficiency residential heating system designed for reliable performance and energy savings. Featuring advanced combustion technology, variable-speed blower motor, electronic ignition, multi-speed operation, and compatibility with various thermostat systems. Below are key sections for safety, features, installation, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting Thermostat 7. Operating Procedures 8. Safety Features 9. Maintenance & Cleaning 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Heat exchanger, blower assembly, gas valve, electronic control board, pressure switches, flame sensor, inducer motor.

FeatureDescription
Heat ExchangerStainless steel construction for efficient heat transfer
Variable Speed BlowerAdjustable airflow for optimal comfort and efficiency
Electronic IgnitionHot surface igniter for reliable startup
Multi-Speed OperationMultiple fan speeds for different heating requirements
Gas ValvePrecise gas flow control with safety shutoff
Control BoardMicroprocessor-based for system monitoring
Pressure SwitchesSafety verification of proper venting
Flame SensorMonitors burner flame presence
Inducer MotorDrafts combustion gases through heat exchanger
Filter AccessEasy-access panel for filter replacement

Installation

Unpack and inspect all components. Ensure proper location with adequate clearance.

  1. Position furnace: Place on stable, level surface with proper clearances.
  2. Connect gas supply: Use approved gas piping with shutoff valve.
  3. Connect electrical: 120V AC power supply with proper grounding.
  4. Connect venting: Install approved vent pipe according to local codes.
  5. Connect thermostat: Low-voltage wiring to control board.
  6. Install air filter: Proper size and orientation.

WARNING! Installation must be performed by qualified HVAC technician. Gas leaks can cause explosion or fire.

First-Time Setup

Power on furnace; verify proper operation sequence.

  1. Check gas connections: Use leak detection solution on all joints.
  2. Verify electrical: Ensure proper voltage and grounding.
  3. Test thermostat: Set to heat mode and verify furnace response.
  4. Check airflow: Verify proper duct connections and filter installation.
  5. Monitor startup: Observe complete heating cycle for normal operation.

CAUTION! Never bypass safety devices. Test carbon monoxide detectors after installation.

Specifications

Controls and Settings

Access control board via front service panel. Thermostat controls system operation.

Control Board LEDs: Power, heat, error codes. DIP switches for blower speeds, thermostat type.

Temperature Settings: Thermostat heat/cool settings. Fan Control: Auto/On modes. System Mode: Heat/Off/Cool (if equipped). Advanced Settings: Fan delay, temperature differential, system timing.

Connecting Thermostat

Standard 5-wire thermostat connection: R (power), W (heat), G (fan), Y (cool), C (common).

  1. Turn off power at furnace and thermostat.
  2. Remove old thermostat and label wires.
  3. Connect wires to new thermostat terminals.
  4. Mount thermostat and restore power.
  5. Test all functions: Heat, fan, system mode.

Tip: Use compatible thermostat for optimal performance and efficiency.

Operating Procedures

Normal heating cycle operation and seasonal startup.

  1. Set thermostat: Adjust to desired temperature in heat mode.
  2. System startup: Inducer motor runs, pressure switch verifies, igniter heats, gas valve opens.
  3. Flame establishment: Burner ignition, flame sensor confirmation, blower activation.
  4. Normal operation: Continuous heating until thermostat satisfied.
  5. Shutdown: Gas valve closes, blower continues for post-purge.
  6. Seasonal shutdown: Turn off gas and electrical if not used during warm months.

WARNING! Never operate with access panels removed. Keep combustible materials away from furnace.

Safety Features

Flame rollout switches: Shut off gas if flame escapes burner area. High limit switch: Prevents overheating. Pressure switches: Ensure proper venting. Flame sensor: Confirms burner ignition. Gas valve: Automatic shutoff during faults.

Maintenance & Cleaning

Monthly filter inspection/replacement. Annual professional maintenance recommended.

  1. Air filter: Replace every 1-3 months depending on usage.
  2. Burners: Clean annually to remove dust and debris.
  3. Flame sensor: Clean with emery cloth annually.
  4. Blower assembly: Vacuum dust and debris annually.
  5. Vent system: Inspect for obstructions annually.

CAUTION! Always turn off gas and electrical power before servicing. Use only approved replacement parts.

Regulatory Information

UL listed and ANSI certified. Complies with ASHRAE standards. Meets DOE efficiency requirements. Manufactured to ISO 9001 quality standards. For technical support, visit www.airease.com or contact 1-800-555-HEAT. All installations must comply with local building codes and NFPA standards.

Troubleshooting

SymptomPossible CauseCorrective Action
No heatThermostat setting, power, gas supplyCheck thermostat setting, circuit breaker, gas valve position
Furnace not startingSafety lockout, pressure switchReset power, check venting, verify pressure switch operation
Short cyclingDirty filter, high limitReplace filter, check airflow, verify limit switch
Blower not runningMotor, capacitor, control boardCheck power to motor, test capacitor, verify control signals
Unusual noisesLoose components, airflowTighten access panels, check ductwork, verify blower wheel

Reset: Turn power off for 30 seconds then restore.

Service: 1-800-555-HEAT; www.airease.com