Air Ease Gas Furnace Manual

The Air Ease Gas Furnace is a high-efficiency heating system designed for residential use, featuring advanced combustion technology, multiple heating stages, variable-speed blower motor, electronic ignition system, built-in safety controls, diagnostic LED indicators, and compatibility with standard thermostat systems. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting Thermostat 7. Operation 8. Maintenance 9. Safety Features 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Gas valve assembly, heat exchanger, blower motor, electronic ignition, pressure switches, flame sensor, diagnostic board, filter compartment.

FeatureDescription
Gas valvePrecise gas flow control with multiple stages
Heat exchangerStainless steel construction for high efficiency
Blower motorVariable-speed ECM motor for quiet operation
Electronic ignitionHot surface igniter for reliable startup
Pressure switchesSafety verification of proper venting
Flame sensorMonitors burner flame presence
Diagnostic LEDFlashing codes for troubleshooting
Filter compartmentEasy-access standard 1-inch filter
Safety shutoffAutomatic gas shutoff in case of malfunction
Thermostat connectionStandard 24VAC terminal connections

Installation

Unpack and inspect all components. Ensure proper clearances and ventilation.

  1. Location selection: Choose well-ventilated area with proper clearances to combustibles.
  2. Gas line connection: Use approved gas piping and fittings; pressure test for leaks.
  3. Vent system: Install PVC vent pipes according to local codes and manufacturer specifications.
  4. Electrical connection: Connect to 120V power supply with proper grounding.
  5. Thermostat wiring: Connect standard 24V thermostat wires to control board.

WARNING! Installation must be performed by qualified HVAC technician. Gas leaks can cause explosion or fire.

First-Time Setup

Complete installation verification before initial startup.

  1. Gas pressure check: Verify inlet and manifold pressures are within specifications.
  2. Vent system verification: Confirm proper draft and no obstructions.
  3. Electrical verification: Check all connections and proper voltage.
  4. Initial startup: Follow lighting instructions; observe first ignition cycle.
  5. System check: Verify proper heating operation and thermostat control.

CAUTION! Never bypass safety controls. Carbon monoxide poisoning can occur with improper installation.

Specifications

Controls and Settings

Access control board via front panel. Diagnostic LED provides status codes.

Control Board: Power switch, diagnostic LED, dip switch settings, terminal connections.

Operating Modes: HEAT, COOL, FAN ONLY. Blower Settings: Continuous fan, auto mode. Temperature Control: Via thermostat. Diagnostic Codes: LED flash patterns indicate specific faults. Dip Switches: Heat anticipator settings, blower delays, staging configuration.

Connecting Thermostat

Standard 24V thermostat connection with R, W, Y, G, C terminals.

  1. Turn off power to furnace before wiring.
  2. Identify thermostat wires: R (24V), W (heat), Y (cool), G (fan), C (common).
  3. Connect wires to corresponding terminals on control board.
  4. Program thermostat for heating operation and desired temperature settings.

Tip: Use programmable thermostat for optimal energy efficiency and comfort.

Operation

Normal heating cycle operation and system functions.

  1. Thermostat call: Thermostat calls for heat when temperature drops below set point.
  2. Inducer operation: Inducer motor starts to establish draft.
  3. Pressure switch: Verifies proper draft before ignition.
  4. Ignition sequence: Hot surface igniter glows, gas valve opens.
  5. Flame verification: Flame sensor confirms burner ignition.
  6. Blower operation: Blower starts after heat exchanger warm-up delay.
  7. Cycle completion: System shuts down when thermostat satisfied.

WARNING! Never operate furnace with access panels removed. Risk of electric shock and carbon monoxide exposure.

Maintenance

Regular maintenance ensures optimal performance and safety.

  1. Monthly: Check and replace air filter as needed.
  2. Seasonal: Inspect vent system for obstructions or damage.
  3. Annual: Professional inspection and cleaning of burners, heat exchanger, and flue passages.
  4. Biannual: Check gas pressure and combustion analysis.
  5. As needed: Clean flame sensor and inspect electrical connections.

CAUTION! Always turn off power and gas supply before performing any maintenance.

Safety Features

Multiple safety systems protect against hazardous conditions.

Safety FeatureFunction
Flame rollout switchesDetects flame outside combustion chamber
High limit switchPrevents overheating of heat exchanger
Pressure switchesEnsures proper venting before ignition
Flame sensorConfirms burner ignition within safety time
Gas valveAutomatic shutoff if ignition fails
Carbon monoxide detectorRecommended for additional safety

Regulatory Information

UL certified for safety standards. ANSI Z21.47 compliant for gas-fired central furnaces. Meets DOE energy efficiency standards. Manufactured in compliance with EPA regulations. For technical support, contact Air Ease customer service at 1-800-448-0123 or visit www.airease.com.

Troubleshooting

SymptomPossible CauseCorrective Action
Furnace won't startPower, thermostat, safety lockoutCheck power switch, thermostat settings, reset if locked out.
No heatGas supply, ignition failureVerify gas valve on, check for ignition attempts, inspect flame sensor.
Short cyclingDirty filter, airflow restrictionReplace filter, check vents and registers for obstructions.
Blower won't stopThermostat fan settingCheck thermostat fan setting (auto vs. on), inspect fan relay.
Unusual noisesMotor bearings, loose componentsInspect blower wheel, motor mounts, tighten loose panels.
Error codes flashingSystem fault detectedCount LED flashes and refer to diagnostic code chart in manual.

Reset: Power cycle furnace by turning switch off for 30 seconds then on.

Service: 1-800-448-0123; www.airease.com