The Amana 95 Furnace is a high-efficiency gas furnace with 95% AFUE rating, featuring variable-speed blower technology, electronic ignition, multi-speed operation, diagnostic LED indicator, built-in condensate removal system, and compatibility with standard thermostat systems. Designed for residential heating applications with natural gas or propane capability. Below are key sections for safety, features, installation, operation, maintenance, and troubleshooting.
Key components: Stainless steel heat exchanger, variable-speed ECM blower motor, electronic control board, pressure switches, gas valve, igniter, flame sensor, condensate drain system.
| Feature | Description |
|---|---|
| Heat Exchanger | Stainless steel primary and secondary heat exchangers |
| Blower Motor | Variable-speed ECM for quiet operation and efficiency |
| Ignition System | Hot surface igniter with flame sensor |
| Venting | PVC pipe compatible for sidewall or roof termination |
| Gas Valve | Multi-stage gas valve for precise fuel control |
| Control Board | Microprocessor-based with diagnostic LED |
| Pressure Switches | Verify proper venting operation |
| Thermostat Connections | Standard 24V connections for heating/cooling |
| Filter System | Standard 1-inch or 4-inch media filter compatible |
| Condensate Drain | Built-in trap and drain connections |
Unpack and inspect all components. Ensure proper clearances and location requirements.
WARNING! Installation must be performed by qualified HVAC technician. Gas furnaces can produce carbon monoxide - ensure proper venting.
Complete installation verification before initial startup.
CAUTION! Never bypass safety controls. Always verify proper operation before leaving installation.
Integrated control board manages all furnace operations with diagnostic capabilities.
Control Board: LED status light indicates system operation and fault codes. DIP switches for blower speed and configuration settings.
Operation Sequence: Call for heat from thermostat → Inducer motor starts → Pressure switch verification → Hot surface igniter activates → Gas valve opens → Flame sensor verification → Main blower starts → Heating cycle continues until thermostat satisfied.
Thermostat Settings: Compatible with standard 24V thermostats; programmable thermostats recommended for maximum efficiency.
Direct vent system using PVC pipe for both intake and exhaust.
Tip: Always follow local building codes and manufacturer specifications for venting installations.
Regular maintenance ensures optimal performance and longevity.
WARNING! Turn off electrical power and gas supply before performing any maintenance. Only qualified technicians should service gas components.
Multiple safety systems protect against hazardous conditions. Flame rollout switch: Detects improper burner operation. Limit switches: Prevent overheating. Pressure switches: Verify proper venting. Flame sensor: Confirms burner ignition. Ignition control: Safe start-up sequence.
Keep furnace area clean and free of combustible materials. Use vacuum with soft brush attachment for cleaning exterior surfaces.
CAUTION! Never use water or liquid cleaners on electrical components. Keep ventilation openings clear of obstructions.
ANSI Z21.47/CSA 2.3: Certified for US and Canadian safety standards. UL listed components. Meets DOE energy efficiency requirements. For technical support, contact Amana Heating & Air Conditioning at 1-888-292-6262 or visit www.amana-hac.com. Installation must comply with local building codes and utility requirements.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Furnace won't start | Power, thermostat, door switch | Check circuit breaker, thermostat settings, door switch engagement |
| No heat | Gas supply, igniter, flame sensor | Verify gas valve on, check igniter operation, clean flame sensor |
| Short cycling | Filter, limit switch, airflow | Replace dirty filter, check for restricted airflow, verify limit switch |
| Blower won't stop | Thermostat, control board | Check thermostat fan setting, control board operation |
| Error codes flashing | Various system faults | Refer to diagnostic chart in service manual for specific code meaning |
Reset: Turn power off for 30 seconds then restore to reset control board.
Service: 1-888-292-6262; www.amana-hac.com