amana distinction furnace manual h8070

The Amana Distinction Furnace H8070 is a high-efficiency gas furnace featuring variable-speed blower technology, electronic ignition, multi-speed operation, and advanced diagnostic controls. With AFUE ratings up to 96%, this furnace provides reliable heating for residential applications. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation Requirements 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Operating Instructions 7. Maintenance Procedures 8. Safety Features 9. Care & Cleaning 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Variable-speed ECM blower motor, hot surface igniter, stainless steel heat exchanger, integrated control board, pressure switches, flame sensor, and diagnostic LED.

FeatureDescription
Variable-speed blowerProvides consistent airflow and quiet operation
Stainless steel heat exchangerDurable construction for long service life
Electronic ignitionEnergy-efficient hot surface ignition system
Multi-speed operationAdjustable airflow for optimal comfort
Diagnostic control boardLED status indicators for troubleshooting
Pressure switchesSafety monitoring of venting system
Flame sensorEnsures proper burner operation
Gas valvePrecise fuel control for efficiency
Filter cabinetStandard 1-inch or 4-inch media filter compatible
Drain connectionsCondensate removal system

Installation Requirements

Unpack and inspect all components. Ensure proper clearances and venting.

  1. Location: Install in approved area with proper clearances (minimum 1" from combustible materials).
  2. Venting: Use approved PVC piping for intake and exhaust; maintain proper slope for condensate drainage.
  3. Gas connection: Use black iron pipe with proper thread sealant; pressure test for leaks.
  4. Electrical: Connect to 120V AC power; proper grounding required.
  5. Drain line: Install condensate drain with trap and proper routing.

WARNING! Installation must be performed by qualified HVAC technician. Follow all local codes and manufacturer specifications.

First-Time Setup

Power on furnace; follow startup sequence.

  1. System check: Verify all connections are secure and proper gas pressure.
  2. Initial startup: Turn on power; control board will perform self-test.
  3. Blower settings: Adjust dip switches for proper airflow based on installation requirements.
  4. Thermostat configuration: Compatible with most standard and programmable thermostats.
  5. Test operation: Verify proper ignition sequence and heating operation.

CAUTION! Never bypass safety controls. Ensure proper ventilation during initial startup.

Specifications

Controls and Settings

Access control board via front panel. Integrated diagnostic LED provides status codes.

Control Board: POWER switch, STATUS LED, DIP switches for blower settings, fuse.

Operating Modes: HEAT, COOL, FAN. Blower Settings: Adjustable airflow via DIP switches. Temperature Control: Via external thermostat. Diagnostic Codes: LED flash patterns indicate specific error conditions. Safety Controls: Pressure switches, flame rollout switches, high limit control.

Operating Instructions

Normal operation controlled by thermostat settings.

  1. Set thermostat to desired temperature and HEAT mode.
  2. Furnace will initiate call for heat sequence.
  3. Blower will start; igniter will glow; gas valve will open.
  4. Flame sensor confirms ignition; main burner operates.
  5. Blower adjusts speed for optimal heating.
  6. When thermostat satisfied, gas valve closes; blower continues for post-purge.

Tip: Allow furnace to complete entire cycle; do not interrupt operation.

Maintenance Procedures

Regular maintenance ensures optimal performance and efficiency.

  1. Monthly: Check and replace air filter as needed.
  2. Seasonal: Inspect burners and heat exchanger for debris.
  3. Annual: Professional inspection and cleaning recommended.
  4. Check condensate drain line for blockages.
  5. Verify proper venting and clearances.
  6. Test safety controls and operation.

WARNING! Turn off power and gas supply before performing any maintenance. Only qualified technicians should service internal components.

Safety Features

Multiple safety systems protect against hazardous conditions. Pressure switches monitor venting. Flame rollout switches protect against improper combustion. High limit control prevents overheating. Ignition control ensures proper burner operation.

Care & Cleaning

Turn off power before cleaning. Keep area around furnace clear of combustible materials.

CAUTION! Do not use compressed air to clean internal components. Never spray cleaning solutions into furnace.

Regulatory Information

UL listed; ANSI Z21.47 compliant. Certified for residential installation. Manufactured to meet ENERGY STAR® requirements where applicable. Copyright © Amana Heating & Air Conditioning. For support, visit www.amana-hac.com or contact 1-888-292-6262.

Troubleshooting

SymptomPossible CauseCorrective Action
Furnace won't startPower/thermostatCheck circuit breaker; verify thermostat settings; ensure door panels secure.
No heatGas supply/ignitionVerify gas valve open; check for error codes; inspect flame sensor.
Short cyclingFilter/ventingReplace dirty filter; check for blocked vents; verify proper airflow.
Blower not runningMotor/controlsCheck blower door switch; verify motor operation; inspect control board.
Error codes flashingSystem faultRefer to diagnostic chart in manual; note LED flash pattern.

Reset: Turn power off for 30 seconds then restore. If problem persists, call for service.

Service: 1-888-292-6262; www.amana-hac.com