Amana Electric Furnace AMV 90704 Manual

The Amana AMV 90704 is a high-efficiency electric furnace designed for residential heating applications. This furnace features multiple heating stages, variable speed blower motor, durable construction, and advanced safety controls. Below are key sections for safety, features, installation, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Electrical Connections 7. Operation 8. Maintenance 9. Safety Features 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Electric heating elements, Variable speed blower motor, Control board, Safety switches, Air filter compartment, Service access panels.

FeatureDescription
Heating CapacityMultiple stages up to specified BTU output
Blower MotorVariable speed ECM motor for efficiency
Heating ElementsNickel-chromium electric heating coils
Control BoardMicroprocessor-based for precise control
Safety SwitchesHigh-limit and rollout protection
Air FilterStandard 1-inch or 4-inch media filter
Service AccessRemovable panels for maintenance
Wiring ConnectionsClearly labeled terminal blocks
Drain ConnectionFor humidifier or AC coil if installed
Voltage Rating240V AC, 60Hz operation

Installation

Unpack and inspect contents. Ensure proper location and clearances.

  1. Position furnace: Place on stable, level surface with proper clearances.
  2. Ductwork connection: Connect supply and return ducts securely.
  3. Electrical connections: Connect to 240V power supply with proper disconnect.
  4. Thermostat wiring: Connect compatible thermostat following wiring diagram.
  5. Air filter installation: Install appropriate filter in filter rack.

WARNING! Installation must be performed by qualified HVAC technician. Ensure power is disconnected during installation.

First-Time Setup

Power on furnace; verify proper operation.

  1. Power connection: Ensure proper voltage and phase at disconnect.
  2. Thermostat setup: Program thermostat for heating operation.
  3. Blower settings: Adjust blower speed if required for application.
  4. Safety check: Verify all safety switches are functional.
  5. Test operation: Run through complete heating cycle.

CAUTION! Always follow local electrical codes. Test safety controls before regular operation.

Specifications

Controls and Settings

Access control board via service panel. Thermostat controls heating operation.

Control Board: LED status lights, DIP switch settings, terminal connections.

Heating Stages: Multiple stage operation for efficiency. Blower Control: Variable speed settings for different applications. Temperature Limits: Adjustable high-limit settings. Diagnostic Lights: LED indicators for troubleshooting. DIP Switches: Configuration for blower speeds and timing.

Electrical Connections

Power supply: 240V AC. Thermostat: Low voltage connections. Safety circuits: High voltage disconnects.

  1. Turn off power at main disconnect before servicing.
  2. Verify proper voltage and phase at power terminals.
  3. Connect thermostat following wiring diagram.
  4. Ensure all connections are tight and secure.

Tip: Use proper gauge wire for all electrical connections.

Operation

Normal heating cycle operation and sequence.

  1. Thermostat call: Thermostat calls for heat.
  2. Blower start: Indoor blower starts after delay.
  3. Heating activation: Heating elements energize in sequence.
  4. Temperature monitoring: Control board monitors temperatures.
  5. Cycle completion: Heating elements de-energize when satisfied.
  6. Blower run-on: Blower continues for post-purge cycle.

WARNING! Do not override safety controls. Contact technician if abnormal operation occurs.

Maintenance

Regular maintenance ensures optimal performance and longevity.

  1. Monthly: Check and replace air filter as needed.
  2. Seasonal: Inspect electrical connections and components.
  3. Annual: Professional inspection and cleaning.
  4. As needed: Clean blower assembly and heat exchanger.

CAUTION! Always disconnect power before performing maintenance.

Safety Features

High-limit switches: Prevent overheating. Fusible links: Protect against electrical faults. Door safety switches: Disable operation when panels removed. Overcurrent protection: Circuit breakers or fuses.

Regulatory Information

UL listed and meets applicable safety standards. Complies with NEC and local electrical codes. Manufactured to Amana quality standards. For technical support, contact Amana Customer Service at 1-888-292-6262 or visit www.amana-hac.com.

Troubleshooting

SymptomPossible CauseCorrective Action
No heatPower, thermostat, safety switchCheck power supply; verify thermostat setting; reset safety switches.
Blower not runningMotor, capacitor, control boardCheck motor operation; test capacitor; verify control board signals.
Insufficient heatFilter, elements, airflowReplace filter; check heating elements; verify proper airflow.
Frequent cyclingThermostat, limit switchCheck thermostat location; verify limit switch operation.
Error codesControl board diagnosticsRefer to diagnostic chart; check LED status lights.

Reset: Power cycle at disconnect if safe to do so.

Service: 1-888-292-6262; www.amana-hac.com