The Amana AMH80804BNBB is a high-efficiency gas furnace with 80% AFUE rating, single-stage operation, multi-speed blower motor, durable heat exchanger, electronic ignition system, built-in draft inducer, safety controls, and compatibility with standard thermostat systems. Designed for residential use with natural gas, it features easy installation, quiet operation, and reliable heating performance. Below are key sections for safety, features, installation, operation, maintenance, and troubleshooting.
Key components: Durable heat exchanger, electronic ignition system, multi-speed blower motor, draft inducer assembly, gas valve, pressure switches, flame sensor, and control board.
| Feature | Description |
|---|---|
| Heat Exchanger | Durable construction for efficient heat transfer |
| Electronic Ignition | Reliable spark ignition system |
| Blower Motor | Multi-speed for optimal airflow |
| Draft Inducer | Ensures proper venting and combustion |
| Gas Valve | Precise gas flow control |
| Pressure Switches | Safety monitoring of vent system |
| Flame Sensor | Detects burner flame |
| Control Board | System operation and diagnostics |
| Thermostat Connections | Standard 24V connections |
| Safety Controls | Overheat protection and limit switches |
Unpack and inspect all components. Ensure proper location with adequate clearance.
WARNING! Installation must be performed by qualified technician. Gas leaks can cause explosion. Follow all local codes.
After installation, perform initial startup procedure.
CAUTION! Never bypass safety controls. Test carbon monoxide detectors.
Access control board for diagnostic LEDs and dip switch settings. Thermostat controls heating operation.
Control Board: LED status lights, dip switches for blower speeds, diagnostic codes.
Thermostat Settings: Heat mode, fan auto/on, temperature setpoint. Blower Speeds: Adjustable via dip switches for heating operation. Safety Controls: High limit switch, pressure switches, flame rollout switch. Diagnostic LEDs: Flash codes for troubleshooting.
Standard 24V thermostat wiring with R, W, G, C terminals.
Tip: Use thermostat compatible with single-stage gas furnace systems.
Normal heating operation controlled by thermostat.
WARNING! Never operate without proper venting. Report unusual noises or odors immediately.
Regular maintenance ensures optimal performance and safety.
CAUTION! Maintenance should be performed by qualified technician only.
Keep furnace area clean and unobstructed. Replace air filters regularly.
CAUTION! Turn off power before cleaning. Use vacuum for dust removal. Never use water or cleaning fluids.
UL listed and ANSI certified. Complies with applicable safety standards. Natural gas appliance must be installed according to National Fuel Gas Code and local codes. Manufactured by Amana Heating & Air Conditioning. For support, contact 1-888-292-6262 or visit www.amana-hac.com.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Furnace won't start | Power, thermostat, gas | Check power switch, thermostat setting, gas valve |
| No heat | Pilot/ignition, filter | Check ignition sequence, replace air filter |
| Short cycling | Filter, limit switch | Replace filter, check for overheating |
| Blower not running | Motor, capacitor | Check blower motor and capacitor |
| Unusual noises | Blower, inducer | Inspect blower wheel and draft inducer |
Reset: Turn power off for 30 seconds then restore.