The Amana Furnace Parts Manual provides comprehensive information about replacement parts, maintenance procedures, and technical specifications for Amana furnace systems. This manual covers gas and electric furnace models, including part numbers, installation guidelines, troubleshooting tips, and safety precautions for proper furnace operation and maintenance.
Key components: Heat exchanger, blower motor, gas valve, igniter, flame sensor, control board, thermostat, air filter, pressure switch, and venting system.
| Component | Description |
|---|---|
| Heat Exchanger | Transfers heat from combustion gases to air stream |
| Blower Motor | Circulates air through duct system |
| Gas Valve | Controls gas flow to burners |
| Igniter | Ignites gas for combustion |
| Flame Sensor | Detects burner flame presence |
| Control Board | Manages furnace operation and safety controls |
| Thermostat | Regulates temperature settings |
| Air Filter | Filters airborne particles from intake air |
| Pressure Switch | Ensures proper venting operation |
| Venting System | Removes combustion byproducts |
Always follow safety protocols when working with furnace components.
WARNING! Gas furnaces contain high voltage and combustible materials. Only qualified technicians should perform repairs.
Proper installation ensures optimal furnace performance and safety.
CAUTION! Improper installation can cause carbon monoxide hazards and void warranty.
Regular maintenance ensures efficient operation and extends furnace lifespan.
Monthly: Check and replace air filter as needed. Annual: Professional inspection and cleaning.
Maintenance checklist: Clean burners, inspect heat exchanger, check gas pressure, lubricate blower motor, test safety controls, verify venting, check condensate system.
Genuine Amana parts ensure compatibility and performance.
Tip: Record furnace model and serial numbers for quick part identification.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Furnace won't start | Power outage, tripped breaker, faulty thermostat | Check power supply, reset breaker, test thermostat |
| No heat | Pilot light out, gas valve closed, igniter failure | Relight pilot, open gas valve, replace igniter |
| Insufficient heat | Dirty filter, blocked vents, low gas pressure | Replace filter, clear vents, check gas pressure |
| Frequent cycling | Dirty filter, oversized unit, thermostat issues | Clean/replace filter, verify unit size, calibrate thermostat |
| Unusual noises | Loose components, bearing wear, airflow issues | Tighten components, lubricate motor, check airflow |
Reset: Turn thermostat to off position for 30 seconds, then restart.
Amana furnaces come with comprehensive warranty coverage. Limited lifetime warranty on heat exchanger, 10-year parts warranty, 1-year labor warranty. Registration required within 60 days of installation.
Regular care prevents costly repairs and ensures safety.
CAUTION! Always turn off power before cleaning. Use approved cleaning materials only.
UL listed, ANSI Z21.47 compliant, meets DOE efficiency standards. CSA certified for Canadian installations. All furnaces tested and certified for safety and performance standards.
For technical support, parts ordering, or service inquiries: Amana Heating & Air Conditioning, 800-843-0304, www.amana-hac.com. Authorized service centers available nationwide.