Amana GUD115C50A Furnace Service Manual

The Amana GUD115C50A is a high-efficiency gas furnace with 115,000 BTU input capacity, 80% AFUE rating, single-stage operation, natural gas compatibility, multi-speed blower motor, hot surface ignition system, aluminized steel heat exchanger, and integrated diagnostic controls. Below are key sections for safety, technical specifications, installation, operation, maintenance, troubleshooting, and warranty information.

1. Safety Precautions 2. Technical Specifications 3. Installation Requirements 4. Electrical Connections 5. Gas Supply Connections 6. Venting Requirements 7. Startup and Operation 8. Maintenance Procedures 9. Diagnostic Codes 10. Troubleshooting Guide 11. Parts List

Safety Precautions

Critical safety information for proper installation and service.

HazardPrecaution
Gas LeaksCheck all connections with leak detection solution; no open flames
Electrical ShockDisconnect power before servicing; use lockout/tagout procedures
Carbon MonoxideEnsure proper venting; install CO detectors in living spaces
High TemperaturesAllow furnace to cool before servicing internal components
Combustible MaterialsMaintain clearance per installation instructions

Technical Specifications

Installation Requirements

Proper installation guidelines for safe and efficient operation.

  1. Location: Install in dry, clean area with adequate combustion air
  2. Clearances: Maintain 1" sides, 1" rear, 6" front, 24" top
  3. Combustion Air: Ensure adequate fresh air supply per local codes
  4. Drain Line: Install condensate drain with proper slope
  5. Leveling: Ensure furnace is level for proper condensate drainage

WARNING! Installation must comply with local codes and regulations. Professional installation recommended.

Electrical Connections

Wiring and electrical connection procedures.

  1. Disconnect power at main service panel
  2. Connect 120V supply to furnace junction box
  3. Connect thermostat wires to control board terminals
  4. Verify proper grounding of all electrical components
  5. Check blower motor rotation and speed settings

CAUTION! All electrical work must be performed by qualified personnel.

Gas Supply Connections

Natural gas connection and pressure verification.

  1. Use approved gas pipe and fittings
  2. Install sediment trap before gas valve
  3. Check for leaks with approved leak detection solution
  4. Verify manifold pressure: 3.5" W.C. ± 0.3"
  5. Check incoming gas pressure: 7" W.C. minimum

DANGER! Gas leaks can cause explosion or fire. Test all connections thoroughly.

Venting Requirements

Proper vent system installation for safe operation.

Startup and Operation

Initial startup procedure and normal operation sequence.

  1. Verify all connections are secure and proper
  2. Restore electrical power and gas supply
  3. Set thermostat to heating mode and raise temperature
  4. Observe ignition sequence: inducer motor, pressure switch, igniter, gas valve
  5. Verify proper flame and blower operation
  6. Check temperature rise: 35-65°F

Maintenance Procedures

Routine maintenance for optimal performance and longevity.

ComponentMaintenance IntervalProcedure
Air FilterMonthlyClean or replace 1" filter
Blower AssemblyAnnuallyClean blower wheel and housing
Heat ExchangerAnnuallyInspect for cracks or corrosion
BurnersAnnuallyClean and inspect for proper flame
Vent SystemAnnuallyInspect for obstructions or damage

Diagnostic Codes

LED flash codes for troubleshooting control board issues.

Flash PatternDescriptionAction
1 FlashIgnition lockoutCheck gas supply, igniter, flame sensor
2 FlashesPressure switch faultCheck inducer, venting, pressure switch
3 FlashesRollout switch openCheck for restricted airflow, heat exchanger
4 FlashesLimit switch openCheck airflow, filter, blower operation
5 FlashesFlame sensed with gas valve offCheck gas valve, control board

Troubleshooting Guide

SymptomPossible CauseCorrective Action
No heatThermostat, power, gas valveCheck thermostat setting, circuit breaker, gas supply
Furnace won't startDoor switch, limit switchEnsure door properly closed, check limit switches
Short cyclingDirty filter, airflow restrictionReplace filter, check vents and registers
Blower runs continuouslyThermostat fan settingCheck thermostat fan setting (auto/on)
Unusual noisesBlower, inducer motorInspect blower wheel, motor bearings, inducer assembly

Parts List

Common replacement parts for Amana GUD115C50A furnace.

Service Support: 1-888-492-6762; www.amana.com

Amana GUD115C50A Furnace Service Manual © - All Rights Reserved 2025