The Amana GUD115C50A is a high-efficiency gas furnace with 115,000 BTU input capacity, 80% AFUE rating, single-stage operation, natural gas compatibility, multi-speed blower motor, hot surface ignition system, aluminized steel heat exchanger, and integrated diagnostic controls. Below are key sections for safety, technical specifications, installation, operation, maintenance, troubleshooting, and warranty information.
Critical safety information for proper installation and service.
| Hazard | Precaution |
|---|---|
| Gas Leaks | Check all connections with leak detection solution; no open flames |
| Electrical Shock | Disconnect power before servicing; use lockout/tagout procedures |
| Carbon Monoxide | Ensure proper venting; install CO detectors in living spaces |
| High Temperatures | Allow furnace to cool before servicing internal components |
| Combustible Materials | Maintain clearance per installation instructions |
Proper installation guidelines for safe and efficient operation.
WARNING! Installation must comply with local codes and regulations. Professional installation recommended.
Wiring and electrical connection procedures.
CAUTION! All electrical work must be performed by qualified personnel.
Natural gas connection and pressure verification.
DANGER! Gas leaks can cause explosion or fire. Test all connections thoroughly.
Proper vent system installation for safe operation.
Initial startup procedure and normal operation sequence.
Routine maintenance for optimal performance and longevity.
| Component | Maintenance Interval | Procedure |
|---|---|---|
| Air Filter | Monthly | Clean or replace 1" filter |
| Blower Assembly | Annually | Clean blower wheel and housing |
| Heat Exchanger | Annually | Inspect for cracks or corrosion |
| Burners | Annually | Clean and inspect for proper flame |
| Vent System | Annually | Inspect for obstructions or damage |
LED flash codes for troubleshooting control board issues.
| Flash Pattern | Description | Action |
|---|---|---|
| 1 Flash | Ignition lockout | Check gas supply, igniter, flame sensor |
| 2 Flashes | Pressure switch fault | Check inducer, venting, pressure switch |
| 3 Flashes | Rollout switch open | Check for restricted airflow, heat exchanger |
| 4 Flashes | Limit switch open | Check airflow, filter, blower operation |
| 5 Flashes | Flame sensed with gas valve off | Check gas valve, control board |
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No heat | Thermostat, power, gas valve | Check thermostat setting, circuit breaker, gas supply |
| Furnace won't start | Door switch, limit switch | Ensure door properly closed, check limit switches |
| Short cycling | Dirty filter, airflow restriction | Replace filter, check vents and registers |
| Blower runs continuously | Thermostat fan setting | Check thermostat fan setting (auto/on) |
| Unusual noises | Blower, inducer motor | Inspect blower wheel, motor bearings, inducer assembly |
Common replacement parts for Amana GUD115C50A furnace.
Service Support: 1-888-492-6762; www.amana.com