The Armstrong Furnace Parts Manual provides comprehensive information about replacement parts, maintenance procedures, and technical specifications for Armstrong furnace systems. This manual covers gas and electric furnace models, including part numbers, installation guidelines, troubleshooting, and safety precautions for proper furnace operation and maintenance.
Key components: Heat exchanger, blower motor, gas valve, ignition system, control board, thermostat, filters, and safety switches.
| Component | Description |
|---|---|
| Heat Exchanger | Transfers heat from combustion gases to air |
| Blower Motor | Circulates air through duct system |
| Gas Valve | Controls gas flow to burners |
| Ignition System | Hot surface or electronic ignition |
| Control Board | Main system controller |
| Thermostat | Temperature regulation |
| Air Filters | Removes airborne particles |
| Limit Switches | Safety temperature controls |
| Pressure Switches | Ensures proper venting |
| Flue Pipe | Vents combustion gases |
Always follow safety protocols when working with furnace components.
WARNING! Gas furnaces contain hazardous components; only qualified technicians should perform repairs.
Proper installation ensures optimal furnace performance and safety.
CAUTION! Improper installation can cause carbon monoxide hazards and void warranty.
Locate and identify furnace components using model-specific diagrams.
Front Panel: Access door, filter slot, control panel, status lights.
Internal Components: Burners, heat exchanger, blower assembly, gas valve, control board, transformer, igniter, flame sensor, pressure switches, limit switches. Refer to model-specific schematic for exact part locations and part numbers.
Step-by-step component replacement instructions.
Tip: Always use Armstrong genuine replacement parts for optimal performance.
Regular maintenance ensures efficiency and extends furnace life.
WARNING! Neglecting maintenance can lead to system failure and safety hazards.
Electrical system parts and specifications.
| Component | Part Number | Specifications |
|---|---|---|
| Control Board | ARM-101234 | 24V AC, microprocessor controlled |
| Igniter | ARM-101235 | Hot surface, 120V |
| Blower Motor | ARM-101236 | 1/3 HP, 1075 RPM |
| Transformer | ARM-101237 | 120V to 24V, 40VA |
| Limit Switch | ARM-101238 | Auto reset, 200°F |
Gas-related parts and safety components.
| Component | Part Number | Function |
|---|---|---|
| Gas Valve | ARM-201234 | Regulates gas flow |
| Burners | ARM-201235 | Stainless steel, inshot type |
| Flame Sensor | ARM-201236 | Proves flame presence |
| Pressure Switch | ARM-201237 | Verifies draft inducer operation |
| Manifold | ARM-201238 | Distributes gas to burners |
Armstrong furnace warranty coverage and registration.
CAUTION! Warranty void if non-OEM parts used or improper installation.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No heat | Thermostat, power, gas valve | Check thermostat setting, circuit breaker, gas supply |
| Short cycling | Dirty filter, limit switch | Replace filter, check airflow, test limit switch |
| Blower not working | Motor, capacitor, control board | Test motor, replace capacitor, check control board |
| Gas odor | Leaks, improper combustion | Immediately shut off gas, call professional |
| Error codes flashing | Sensor faults, pressure issues | Refer to error code chart in service manual |
Reset: Turn power off for 30 seconds, then restart.