The Atwood 7900 Furnace is a high-efficiency RV furnace designed for reliable heating performance. This forced-air furnace features electronic ignition, multiple heat settings, built-in safety controls, easy installation, and compatibility with 12V DC power systems. Below are key sections for safety, features, installation, operation, maintenance, and troubleshooting.
Key components: Burner assembly, blower motor, heat exchanger, control board, thermostat, exhaust vent, intake air vent.
| Feature | Description |
|---|---|
| Electronic ignition | No standing pilot light for improved efficiency |
| Multi-speed blower | Adjustable airflow for optimal heating |
| Heat exchanger | Stainless steel construction for durability |
| Control board | Microprocessor-controlled operation |
| Thermostat compatibility | Works with standard RV thermostats |
| Exhaust vent | Durable plastic venting system |
| Intake air vent | Separate combustion air intake |
| Safety shut-off | Automatic shut-off for safety conditions |
| Power requirements | 12V DC operation |
| BTU ratings | Multiple output options available |
Unpack and inspect all components. Ensure proper mounting location.
WARNING! Installation must comply with local codes. Ensure proper clearances to combustible materials.
Complete installation verification before initial operation.
CAUTION! Never operate without proper venting. Ensure adequate combustion air supply.
Operation controlled via compatible thermostat. Internal DIP switches for configuration.
Thermostat Controls: Temperature setting, fan mode (auto/on), system on/off.
Internal Settings: Blower speed adjustment, ignition timing, safety lockout timing. Access control board for diagnostic LED codes. Fan delay settings for optimal heat distribution. High altitude compensation if needed.
12V DC power connection requirements.
Tip: Use fused power connection. Check voltage at furnace during operation.
Normal operating sequence and user controls.
WARNING! Never block vents or air intakes. Monitor for proper flame appearance.
Regular maintenance schedule for optimal performance.
CAUTION! Disconnect power before servicing. Only qualified technicians should perform internal repairs.
Built-in safety systems for protection.
| Safety Feature | Function |
|---|---|
| Flame rollout switch | Detects improper burner flames |
| Overheat limit switch | Prevents excessive temperatures |
| Ignition lockout | Locks out after multiple failed ignition attempts |
| Pressure switch | Verifies proper venting operation |
| Airflow sensor | Ensures adequate combustion air |
CSA certified for RV use. Complies with ANSI Z21.44 standards. Manufactured to meet RV industry requirements. For technical support, contact Atwood Customer Service at 1-800-555-ATWOOD or visit www.atwoodmobile.com. Serial number located on unit rating plate.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No ignition | Power, gas supply, control issue | Check 12V power, verify gas valve open, check control board LED codes |
| Blower runs but no heat | Ignition failure, gas valve | Listen for spark, check gas pressure, verify valve operation |
| Short cycling | Overheat, airflow restriction | Check filters, verify venting clear, inspect heat exchanger |
| No blower operation | Motor, capacitor, control | Check voltage to motor, inspect capacitor, verify control signals |
| Lockout condition | Safety switch, flame sense | Reset power, check safety switches, clean flame sensor |
Reset Procedure: Turn thermostat off, disconnect power for 60 seconds, restore power.