The Atwood Excalibur Furnace is a high-efficiency heating system designed for RV and mobile applications, featuring electronic ignition, multi-speed blower, safety shut-off devices, and compatibility with propane/LP gas. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.
Key components: Electronic ignition system, multi-speed blower motor, heat exchanger, gas valve, thermostat control, safety pressure switch, combustion air intake, and exhaust outlet.
| Feature | Description |
|---|---|
| Electronic Ignition | Pilotless ignition for reliable startup |
| Multi-Speed Blower | Adjustable airflow for optimal heating |
| Heat Exchanger | Stainless steel construction for durability |
| Gas Valve | Precision control of propane/LP gas flow |
| Thermostat Control | Compatible with standard RV thermostats |
| Safety Pressure Switch | Monitors combustion air flow |
| Combustion Air Intake | External air supply for safe operation |
| Exhaust Outlet | Vents combustion gases safely outside |
| Power Requirements | 12V DC operation |
| BTU Ratings | Available in multiple heating capacities |
Unpack and inspect contents. Ensure proper location and clearances.
WARNING! Installation must comply with local codes. Use only approved materials. Gas connections must be leak-tested.
Complete installation checks before initial startup.
CAUTION! Never bypass safety devices. Ensure adequate ventilation during operation.
Thermostat control for temperature setting. Manual reset button for safety lockout.
Operation: Set desired temperature on thermostat. Furnace will cycle automatically to maintain temperature.
Blower Speed: Adjustable for optimal airflow and noise levels. Gas Pressure: Factory set - do not adjust unless qualified. Safety Devices: Pressure switch, overheat protection, flame sensor.
Use approved gas line and fittings. Pressure test required.
Tip: Use leak detection solution to check all connections. Never use open flame.
12V DC power required. Proper polarity essential.
WARNING! Reverse polarity can damage control board. Use proper fuse protection.
Direct vent system mandatory for safe operation.
CAUTION! Never operate without proper venting. Blocked vents can cause carbon monoxide hazard.
Annual maintenance recommended. Turn off power and gas before servicing.
CAUTION! Only qualified technicians should perform internal repairs. Keep area around furnace clear.
CSA certified for mobile home use. Complies with ANSI Z21.44 standards. Installation must comply with NFPA 501C, NFPA 54, and NFPA 58. For support, contact Atwood Customer Service at 1-800-555-HEAT or visit www.atwoodmobile.com.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Furnace won't start | Power supply/thermostat | Check 12V power; verify thermostat setting and wiring. |
| No ignition | Gas supply/ignition | Verify gas valve open; check for spark at igniter. |
| Blower runs but no heat | Gas flow/ignition | Check gas pressure; verify proper flame ignition. |
| Short cycling | Overheating/airflow | Clean filters; check for blocked vents; verify proper airflow. |
| Lockout condition | Safety device activation | Reset manual reset button; check pressure switch operation. |
Reset: Manual reset button on control board if equipped.
Service: 1-800-555-HEAT; www.atwoodmobile.com