The Atwood Hydra Flame Furnace is a high-efficiency heating system designed for RV and mobile applications, featuring electronic ignition, multiple heat settings, built-in safety controls, and durable construction. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.
Key components: Electronic ignition system, thermostat control, air intake/exhaust vents, gas valve, blower motor, heat exchanger.
| Feature | Description |
|---|---|
| Electronic Ignition | Pilotless ignition for reliable startup |
| Thermostat Control | Precise temperature regulation |
| Multiple Heat Settings | Adjustable BTU output for efficiency |
| Safety Shut-off | Automatic gas shut-off if flame fails |
| Blower Motor | Forced air distribution |
| Heat Exchanger | Efficient heat transfer |
| Air Intake/Exhaust | Separate venting system |
| Gas Valve | Controls fuel supply |
| Control Board | Electronic operation management |
| Limit Switch | Prevents overheating |
Unpack and inspect contents. Ensure proper location and ventilation.
WARNING! Installation must be performed by qualified technician. Ensure proper ventilation to prevent carbon monoxide buildup.
Power on furnace; follow startup procedure.
CAUTION! Always check for gas leaks before operation. Use soap solution on connections.
Access controls via thermostat or furnace control panel.
Thermostat: Temperature setting, fan control, system on/off.
Furnace Controls: Power switch, reset button, diagnostic lights.
Temperature Settings: Adjustable from 50°F to 90°F. Fan Control: Auto or continuous operation. Heat Settings: Multiple BTU output levels. Safety Settings: High limit control, flame sensor, pressure switch.
Gas connection: Use approved gas line and fittings. Electrical: 12V DC with proper grounding.
Tip: Always use gas leak detector or soap solution to test connections.
Supports automatic and manual operation modes.
WARNING! Never block air intake or exhaust vents. Ensure proper ventilation at all times.
Flame Rollout Switch: Shuts off gas if flame escapes burner area. Limit Switch: Prevents overheating. Pressure Switch: Ensures proper venting. Flame Sensor: Confirms burner ignition.
Turn off power and gas before maintenance. Clean air filters monthly. Inspect burner annually.
CAUTION! Never operate with blocked vents or dirty filters. Regular maintenance required for safe operation.
ANSI Z21.47: Certified for RV use. CSA International: Safety certified. EPA: Compliant with emissions standards. For support, visit www.atwoodmobile.com or contact 1-800-555-HEAT.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No ignition | Power/gas supply | Check 12V power; verify gas valve open; check spark electrode. |
| Furnace short cycles | Dirty filter/overheating | Clean or replace air filter; check venting. |
| No heat output | Gas valve/ignition | Verify gas supply; check ignition system; reset furnace. |
| Blower doesn't start | Motor/control board | Check blower motor; verify control board operation. |
| Error codes flashing | System fault | Refer to diagnostic chart in manual; reset if needed. |
Reset: Turn power off for 30 seconds, then restart.
Service: 1-800-555-HEAT; www.atwoodmobile.com