Atwood Hydro Flame Furnace Service Manual

The Atwood Hydro Flame Furnace is a high-efficiency heating system designed for RV and mobile applications, featuring electronic ignition, multiple heat settings, safety shut-off systems, and easy maintenance access. Below are key sections for safety, features, installation, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting to Power and Fuel 7. Operating Procedures 8. Maintenance Schedule 9. Care & Cleaning 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Electronic ignition system, thermostat control, air intake/exhaust vents, gas valve, combustion chamber, blower motor, and safety sensors.

FeatureDescription
Electronic IgnitionAutomatic spark ignition for reliable startup
Thermostat ControlPrecise temperature regulation
Safety Shut-offAutomatic shutdown if flame failure detected
Multiple Heat SettingsAdjustable BTU output for efficiency
Blower MotorForced air distribution system
Combustion ChamberStainless steel construction for durability
Air Intake/ExhaustDual-port system for proper ventilation
Gas ValveRegulates propane/natural gas flow
Control PanelLED indicators and mode selection
Maintenance AccessEasy-to-remove panels for service

Installation

Unpack and inspect all components. Ensure proper ventilation and clearances.

  1. Mount furnace: Secure to floor or wall using provided brackets
  2. Connect venting: Install intake and exhaust pipes according to specifications
  3. Gas connection: Use approved gas line and fittings; check for leaks
  4. Electrical connection: Connect to 12V DC power source
  5. Thermostat wiring: Connect to compatible thermostat system

WARNING! Installation must comply with local codes. Use only certified technicians for gas connections.

First-Time Setup

Complete installation checks before initial startup.

  1. Gas pressure test: Verify proper gas pressure at valve
  2. Ventilation check: Ensure clear air intake and exhaust paths
  3. Electrical test: Confirm 12V DC power supply
  4. Initial ignition: Follow startup sequence in manual
  5. Calibration: Set thermostat and heat settings

CAUTION! Never bypass safety systems. Test carbon monoxide detectors.

Specifications

Controls and Settings

Control panel includes power switch, thermostat dial, mode selector, and status LEDs.

Remote Thermostat: Temperature setting, fan control, system on/off.

Operating Modes: HEAT, FAN ONLY, OFF. Heat Settings: LOW, MEDIUM, HIGH. Safety Features: Flame sensor, overheat protection, pressure switch, roll-out switch. Maintenance Indicators: Filter status, service required LED.

Connecting to Power and Fuel

Proper connections ensure safe and efficient operation.

  1. Turn off all power and gas supply before connecting
  2. Gas line: Use approved flexible gas line with proper fittings
  3. Electrical: Connect to 12V DC power with correct polarity
  4. Grounding: Ensure proper electrical grounding
  5. Test connections: Check for gas leaks and electrical continuity

Tip: Use gas leak detector solution on all connections.

Operating Procedures

Standard operating sequence for normal use.

  1. Power on: Switch control panel to ON position
  2. Set thermostat: Adjust to desired temperature
  3. Select mode: Choose HEAT mode for heating
  4. Startup: System will initiate ignition sequence automatically
  5. Monitor: Watch for proper ignition and flame establishment
  6. Adjust settings: Modify heat output as needed
  7. Shutdown: Turn thermostat to lowest setting before power off

WARNING! Never operate without proper ventilation. Monitor for unusual odors or sounds.

Maintenance Schedule

Regular maintenance ensures optimal performance and safety.

IntervalMaintenance Task
MonthlyCheck air filter; clean if dirty
SeasonalInspect venting system; clean combustion chamber
AnnualProfessional inspection and cleaning
Every 2 yearsReplace thermocouple and flame sensor
As neededCheck gas connections and electrical wiring

Care & Cleaning

Turn off power and gas supply before cleaning. Use soft brush and compressed air for internal components.

CAUTION! Never use water or liquid cleaners on electrical components. Wear protective equipment when handling combustion chamber.

Regulatory Information

UL certified for RV use. Complies with ANSI Z21.44 standards for gas-fired heaters. CSA certified for Canadian market. Manufactured to meet EPA emissions standards. For technical support, contact Atwood Customer Service at 1-800-555-HEAT or visit www.atwoodmobile.com.

Troubleshooting

SymptomPossible CauseCorrective Action
No ignitionGas supply, spark electrodeCheck gas valve; clean spark electrode; verify power
Short cyclingDirty filter, airflow restrictionClean/replace filter; check vent blockage
Blower not workingMotor, wiring, capacitorCheck motor operation; test wiring; replace capacitor if needed
Flame failureDirty sensor, gas pressureClean flame sensor; check gas pressure settings
Unusual odorsDust buildup, combustion issuesClean combustion chamber; check for proper ventilation

Reset Procedure: Turn power off for 30 seconds, then restart.