The Atwood Hydro Flame Furnace Thermostat is a precision temperature control device designed for RV and marine furnace systems. It features digital temperature display, programmable settings, fan control, temperature calibration, battery power indicator, and compatibility with Hydro Flame furnace models. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.
Key components: Digital thermostat display, Temperature control buttons, Mode selection, Fan control, Power indicator, Wiring terminals.
| Feature | Description |
|---|---|
| Digital Display | Shows current temperature and settings |
| Temperature Control | Precise temperature adjustment in 1° increments |
| Mode Selection | Heat, Off, and Fan-only modes |
| Fan Control | Automatic and manual fan operation |
| Power Indicator | Shows thermostat power status |
| Wiring Terminals | For furnace connection (R, W, G terminals) |
| Temperature Calibration | Adjustable temperature offset |
| Battery Backup | Maintains settings during power loss |
| LED Indicators | System status and error codes |
| Mounting Plate | For wall installation |
Unpack and inspect contents. Ensure proper location for accurate temperature reading.
WARNING! Always disconnect power before installation. Ensure proper wiring to prevent damage.
Power on thermostat; follow initial setup procedure.
CAUTION! Ensure thermostat is level and away from drafts for accurate temperature reading.
Access settings via front panel buttons. Display shows current temperature and mode.
Buttons: MODE (Heat/Off/Fan), UP arrow, DOWN arrow, FAN (Auto/On), SET/HOLD.
Temperature Setting: Use UP/DOWN arrows to set desired temperature. Mode Selection: Heat for furnace operation, Off to turn system off, Fan for fan-only operation. Fan Control: Auto (fan runs with heat), On (continuous fan). Temperature Hold: SET/HOLD maintains current temperature setting. Calibration: Access through hidden menu for temperature offset adjustment.
Standard 3-wire connection to furnace control board.
Tip: Label wires before disconnecting old thermostat for easy installation.
Simple operation for daily temperature control.
WARNING! Do not set temperature below 40°F to prevent furnace damage in cold conditions.
Optimal temperature settings for comfort and efficiency.
Use temperature setbacks when away to save energy. Allow 30 minutes for temperature stabilization after changes.
Regular maintenance ensures accurate operation and longevity.
CAUTION! Never use liquids or abrasive cleaners on display. Disconnect power before cleaning.
UL Listed: Complies with UL Standard 873 for temperature indicating and regulating equipment. CSA Certified: Meets Canadian Standards Association requirements. FCC Part 15: Class B digital device compliant. Copyright © Atwood Mobile Products. For technical support, contact Atwood Customer Service at 1-800-888-3378 or visit www.atwoodmobile.com.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Blank display | No power | Check furnace power; verify wiring connections; test voltage at terminals. |
| Furnace not starting | Thermostat setting/wiring | Ensure mode set to Heat; check temperature setting; verify W terminal connection. |
| Inaccurate temperature | Location/calibration | Relocate away from heat sources; recalibrate temperature offset. |
| Fan not operating | Mode setting/wiring | Check fan mode setting; verify G terminal connection; test fan operation at furnace. |
| Error codes displayed | System fault | Refer to error code chart in furnace manual; reset system power. |
Reset: Turn off power for 30 seconds, then restore.
Service: 1-800-888-3378; www.atwoodmobile.com