The Atwood Hydro Flame Furnace is a high-efficiency heating system designed for RV and mobile applications, featuring automatic ignition, multi-speed blower, safety shut-off systems, and compatibility with propane fuel. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.
Key components: Automatic ignition system, multi-speed blower, thermostat control, propane gas connection, exhaust vent, air intake, safety shut-off valve.
| Feature | Description |
|---|---|
| Automatic Ignition | Electronic spark ignition for reliable startup |
| Multi-speed Blower | Adjustable fan speeds for optimal heat distribution |
| Thermostat Control | Precise temperature regulation |
| Propane Connection | Standard 1/2" NPT gas inlet |
| Safety Shut-off | Automatic gas shut-off in case of flame failure |
| Exhaust Vent | 3-inch diameter vent for combustion gases |
| Air Intake | Fresh air supply for combustion |
| Power Supply | 12V DC operation |
| Heat Output | Adjustable BTU settings |
| Control Panel | LED indicators and mode selection |
Unpack and inspect contents. Ensure proper ventilation and clearances.
WARNING! Installation must be performed by qualified technician. Ensure proper ventilation to prevent carbon monoxide buildup.
Power on furnace; follow startup procedure.
CAUTION! Perform leak test on all gas connections before initial use.
Access controls via thermostat or furnace control panel.
Thermostat: Temperature setting, fan control, mode selection.
Control Panel: Power switch, reset button, LED status indicators (power, ignition, error).
Temperature Settings: Adjust thermostat to desired comfort level. Fan Control: Auto, Low, Medium, High speeds. Mode Selection: Heat, Fan Only, Off. Safety Settings: High limit switch, flame sensor, pressure switch monitoring.
Propane gas connection using approved gas line and fittings.
Tip: Always use two wrenches when connecting gas lines to prevent damage.
Standard operating sequence for heating mode.
WARNING! Never operate without proper ventilation. Ensure exhaust vent is clear.
Multiple safety systems: High limit switch, flame roll-out switch, pressure switch, tip-over switch, oxygen depletion sensor.
Annual maintenance recommended. Turn off power and gas before servicing.
CAUTION! Only qualified technicians should perform internal repairs.
CSA certified for RV use. Complies with ANSI Z21.44 standards. Manufactured to meet RV industry safety requirements. For support, contact Atwood Customer Service at 1-800-555-HEAT or visit www.atwoodmobile.com.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No ignition | Gas supply, power, igniter | Check gas valve; verify 12V power; inspect spark igniter |
| Blower not working | Power, motor, switch | Check fuse; test motor; verify thermostat setting |
| Flame goes out | Draft, sensor, gas pressure | Check venting; clean flame sensor; verify gas pressure |
| Error code flashing | Safety lockout | Reset power; check error code meaning in manual |
| Poor heat output | Airflow, burner, settings | Clean air filter; inspect burner; adjust thermostat |
Reset: Turn power off for 30 seconds then restart.
Service: 1-800-555-HEAT; www.atwoodmobile.com