The Bryant Furnace Thermostat is a programmable temperature control device designed for Bryant heating systems, featuring digital display, programmable schedules, temperature hold functions, system mode selection (heat/cool/off), fan control (auto/on), temperature adjustment, battery backup, filter change reminders, and system diagnostics. Compatible with Bryant furnace models and requires proper wiring installation. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting to HVAC System 7. Programming Schedules 8. Energy Saving Features 9. Maintenance & Care 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Digital display, Mode buttons, Temperature controls, Program schedule buttons, Fan control, Hold function, Battery compartment.

FeatureDescription
Digital DisplayShows current temperature and settings
Mode SelectionHeat/Cool/Off system modes
Temperature ControlUp/Down buttons for temperature adjustment
Program Schedules7-day programmable schedules
Fan ControlAuto/On fan operation modes
Hold FunctionTemporary temperature override
Battery BackupAA batteries for power outage protection
Filter ReminderAlerts for filter replacement
System DiagnosticsError code display for system issues
Backlit DisplayIlluminated for low-light conditions

Installation

Turn off power to HVAC system before installation. Mount on interior wall away from direct sunlight and drafts.

  1. Remove old thermostat: Turn off power, remove cover, label wires, disconnect from terminals.
  2. Mount new baseplate: Level and secure to wall, feed wires through opening.
  3. Connect wires: Match labeled wires to corresponding terminals (R, W, Y, G, C).
  4. Attach thermostat: Snap onto baseplate, restore power to HVAC system.
  5. Configure settings: Follow first-time setup procedure.

WARNING! Always turn off power before installation to prevent electrical shock. Use proper wiring techniques.

First-Time Setup

After installation, configure basic settings for proper operation.

  1. Set date and time: Access TIME menu, set current date and time.
  2. Configure temperature units: Select Fahrenheit or Celsius in SETTINGS.
  3. Set program schedules: Create wake, leave, return, sleep schedules.
  4. Test system operation: Verify heat and cool modes function properly.
  5. Set filter reminder: Program filter change interval (1-12 months).

CAUTION! Ensure proper wiring before restoring power. Incorrect installation may damage HVAC system.

Specifications

Controls and Settings

Access settings via menu buttons. Front panel: MODE, FAN, TEMP UP/DOWN, HOLD, MENU.

Menu Options: TIME/DATE, SCHEDULE, SETTINGS, FILTER, DIAGNOSTICS.

Temperature Control: Adjust setpoint with up/down buttons. Mode Selection: HEAT for furnace operation, COOL for AC, OFF for system shutdown. Fan Control: AUTO (runs with system), ON (continuous operation). Program Schedules: Set different temperatures for wake, leave, return, sleep periods. Hold Function: Temporary override of programmed schedule. Filter Reminder: Programmable interval with reset function.

Connecting to HVAC System

Standard 5-wire connection: R (24V power), W (heat), Y (cool), G (fan), C (common).

  1. Turn off HVAC system power at circuit breaker.
  2. Label existing wires before disconnecting.
  3. Match wire colors to terminal labels.
  4. Ensure secure connections with no exposed copper.
  5. Restore power and test system operation.

Tip: Take photo of original wiring before disconnecting for reference.

Programming Schedules

Create energy-efficient temperature schedules for different times of day.

  1. Access SCHEDULE menu from main display.
  2. Select day or day group (Weekday/Weekend).
  3. Set four periods: Wake, Leave, Return, Sleep.
  4. Adjust temperatures for each period using up/down buttons.
  5. Save schedule and exit menu.
  6. Copy schedule to other days if desired.
  7. Enable/disable schedule as needed.

WARNING! Do not set extreme temperature differentials that may strain HVAC system.

Energy Saving Features

Programmable schedules reduce energy consumption. Adaptive Recovery: Learns system cycle times to reach setpoints efficiently. Temperature Limits: Set minimum and maximum temperature boundaries. Filter Monitoring: Reminds when filter replacement is due for optimal efficiency.

Maintenance & Care

Clean display with soft, dry cloth. Replace batteries annually. Check wiring connections periodically.

CAUTION! Do not use liquid cleaners or abrasives. Turn off power before any maintenance.

Regulatory Information

UL Listed: Meets safety standards for HVAC controls. FCC Part 15: Class B digital device compliant. Energy Star: Meets energy efficiency guidelines. Copyright © 2025 Bryant; trademarks of Carrier Corporation. For technical support, visit www.bryant.com or contact 1-800-BRYANT-1.

Troubleshooting

SymptomPossible CauseCorrective Action
Blank displayPower loss/dead batteriesCheck circuit breaker; replace AA batteries; verify wiring.
System not respondingIncorrect mode/wiringVerify mode setting; check thermostat wiring connections.
Inaccurate temperatureLocation/calibrationRelocate away from heat sources; check temperature calibration.
Schedule not followingHold active/program errorCancel hold function; reprogram schedule settings.
Error codes displayedSystem faultNote error code; consult HVAC technician for diagnosis.

Reset: Remove batteries and disconnect power for 30 seconds to reset.

Service: 1-800-BRYANT-1; www.bryant.com