The Carrier 58CVA is a high-efficiency gas furnace with variable-speed blower motor, multi-speed inducer assembly, and advanced diagnostic controls. This upflow/horizontal flow furnace features two-stage gas valve operation, hot surface ignition, and compatibility with various thermostat systems. Below are key sections for safety, specifications, installation procedures, wiring, startup, and troubleshooting.
Key components: Two-stage gas valve, variable-speed ECM blower motor, hot surface ignitor, induced draft motor, pressure switches, flame sensor, and integrated control board.
| Feature | Description |
|---|---|
| Two-stage gas valve | Provides high and low fire operation for improved comfort and efficiency |
| Variable-speed ECM blower | Adjusts airflow for optimal performance and quiet operation |
| Hot surface ignitor | Reliable electronic ignition system |
| Induced draft motor | Ensures proper venting and combustion |
| Pressure switches | Safety devices to verify proper venting |
| Flame sensor | Detects flame presence for safety shutdown |
| Integrated control board | Manages furnace operation and diagnostics |
| Multi-speed inducer | Variable speed for optimal combustion |
| Diagnostic LED | Flashing codes for troubleshooting |
| Filter access | Easy front-access for filter changes |
Read all instructions before installation. Follow local codes and manufacturer guidelines.
WARNING! Failure to follow safety procedures may result in fire, explosion, carbon monoxide poisoning, or electrical shock. Installation must comply with all local codes and ordinances.
Professional installation recommended. Verify all components are included and undamaged.
CAUTION! Furnace must be installed by qualified personnel familiar with gas-fired equipment and local codes.
Install in clean, dry area with adequate combustion air and service access.
Minimum Clearances: 1" from combustible materials on sides and rear, 24" front service clearance, 6" above unit for vent clearance.
Location: Indoor installation only. Must be protected from water and corrosive elements. Ensure level installation with proper support.
Proper venting is critical for safe operation. Follow manufacturer guidelines for vent pipe sizing and installation.
Tip: Test vent system for leaks before final installation.
Use black iron or approved flexible gas connector. Verify gas type and pressure.
WARNING! Gas leak testing is mandatory. Never use open flame to check for leaks.
Follow NEC and local electrical codes. Use proper wire sizing and overcurrent protection.
CAUTION! Electrical shock hazard. Always disconnect power before servicing.
Proper duct sizing and sealing are essential for efficient operation.
Tip: Perform airflow measurements after installation to verify proper CFM.
Complete system verification before placing in service.
WARNING! Carbon monoxide hazard. Verify proper combustion and venting before leaving unit operational.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No heat | Power, thermostat, gas supply | Check power, thermostat setting, gas valve position, fuses |
| Furnace locks out | Pressure switch, flame sensor | Check pressure switch tubing, clean flame sensor, verify venting |
| Blower not running | Motor, capacitor, control board | Check voltage to motor, test capacitor, verify control signals |
| Ignition failure | Hot surface ignitor, gas valve | Test ignitor for continuity, check gas pressure, verify spark gap |
| Poor airflow | Filter, ductwork, blower | Replace filter, check for duct restrictions, verify blower speed |
Diagnostic Codes: Refer to LED flash codes on control board for specific error indications.
Service: Contact authorized Carrier dealer for technical support. Carrier Customer Care: 1-800-CARRIER