The Carrier 58PAV070-12 is a high-efficiency gas furnace with 70,000 BTU input capacity, 80% AFUE rating, single-stage operation, induced draft combustion system, hot surface ignition, multi-speed blower motor, and built-in diagnostic system. Designed for residential use with natural gas, featuring safety controls, filter access, and compatibility with standard thermostat systems. Below are key sections for safety, features, installation, operation, maintenance, and troubleshooting.
Key components: Gas valve, inducer motor, heat exchanger, blower assembly, control board, pressure switches, flame sensor, hot surface ignitor.
| Feature | Description |
|---|---|
| Input Capacity | 70,000 BTU/hr natural gas |
| Efficiency Rating | 80% AFUE |
| Blower Motor | Multi-speed PSC motor |
| Ignition System | Hot surface direct ignition |
| Venting | PVC or ABS plastic pipe |
| Filter Size | 16x25x1 inch standard |
| Gas Connection | 1/2-inch NPT |
| Electrical | 120V, 60Hz, 1.5A |
| Control Board | Integrated diagnostic LED |
| Warranty | 20-year heat exchanger limited |
Professional installation required. Verify local codes and obtain permits.
WARNING! Gas appliances can be hazardous; installation must be performed by qualified technician.
After installation, perform initial startup procedure.
CAUTION! Never bypass safety controls; ensure proper ventilation.
Integrated control board with diagnostic LED. Access door safety switch.
Operation Sequence: Thermostat call → Inducer motor starts → Pressure switch proves → Hot surface ignition → Gas valve opens → Flame established → Blower starts after delay.
Diagnostic LED: Flashing codes indicate system status and fault conditions. Refer to fault code chart on inner door panel.
Compatible with standard 24V thermostats. Terminal designations: R (power), W (heat), G (fan), C (common).
Tip: For optimal performance, use programmable thermostat.
Regular maintenance ensures efficiency and safety.
WARNING! Disconnect power before servicing; only qualified technicians should perform internal maintenance.
Multiple safety systems: Flame rollout switch, high limit switch, pressure switches, door safety switch, flame sensor.
Carbon monoxide detection: Install CO detectors near sleeping areas. Never operate with blocked vents or restricted airflow.
Exterior: Wipe with damp cloth; mild detergent if needed. Keep area around furnace clean and unobstructed.
CAUTION! Never use water or cleaners on electrical components. Keep combustion area clear of debris.
UL listed; ANSI Z21.47 compliant. Natural gas installation must comply with NFPA 54. Electrical installation per NEC. For support, contact Carrier at 1-800-227-7437 or visit www.carrier.com.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Furnace won't start | Power/thermostat | Check circuit breaker; verify thermostat setting; replace batteries. |
| No heat | Gas supply/ignition | Verify gas valve on; check pilot/ignition; inspect filter. |
| Short cycling | Dirty filter/overheat | Replace air filter; check venting; verify proper airflow. |
| Blower won't stop | Thermostat/fan switch | Check thermostat fan setting; inspect fan limit control. |
| Unusual noises | Motor/bearings | Lubricate if required; check for obstructions; inspect blower wheel. |
Reset: Power cycle furnace; wait 5 minutes for automatic reset.
Service: 1-800-227-7437; www.carrier.com