The Carrier Weathermaker Infinity is a high-efficiency gas furnace system featuring variable-speed technology, modulating gas valve, Infinity System control, two-stage heating operation, durable heat exchanger, quiet operation, and advanced diagnostics. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.
Key components: Variable-speed blower motor, modulating gas valve, Infinity control system, heat exchanger, igniter, flame sensor, pressure switches, inducer motor.
| Feature | Description |
|---|---|
| Variable-speed blower | Provides precise airflow control for optimal comfort |
| Modulating gas valve | Adjusts gas flow in 1% increments for precise temperature control |
| Infinity System control | Advanced thermostat interface with system diagnostics |
| Two-stage heating | Operates at low stage for mild weather, high stage for cold weather |
| Heat exchanger | Stainless steel construction for durability and efficiency |
| Quiet operation | Insulated cabinet and variable-speed technology reduce noise |
| Advanced diagnostics | LED status codes for troubleshooting |
| Pressure switches | Safety devices to verify proper venting |
| Flame sensor | Detects burner flame for safe operation |
| Inducer motor | Removes combustion gases through vent system |
Unpack and inspect all components. Ensure proper location and clearances.
WARNING! Gas furnaces produce carbon monoxide; proper venting is critical. Only qualified technicians should install.
Power on furnace; follow startup procedure.
CAUTION! Never bypass safety devices. Follow all startup procedures exactly.
Access system via Infinity control thermostat. Status lights on control board indicate system operation.
Infinity Control: Temperature setting, fan control, system mode, schedule programming, system status, diagnostic codes.
Heating Settings: Temperature setpoint, fan operation (auto/on), system mode (heat/off), schedule programming. Advanced Settings: Dehumidification control, air filtration, system alerts, service reminders. Diagnostics: LED status codes, error history, system performance data.
Gas line: 1/2" or 3/4" black iron pipe. Electrical: 120V dedicated circuit. Vent: PVC or metal. Thermostat: Infinity control communication wires.
Tip: Use approved pipe thread compound on gas connections. Follow local codes for all installations.
Regular maintenance ensures optimal performance and safety.
WARNING! Turn off gas and electrical power before performing any maintenance. Only qualified technicians should service gas components.
Multiple safety systems: Flame rollout switches, high limit switches, pressure switches, igniter safety, gas valve safety shutoff.
Turn off power before cleaning. Keep area around furnace clear. Clean or replace air filter regularly.
CAUTION! Do not use water or cleaning solvents on electrical components. Keep combustion air intake clear.
ANSI Z21.47: Certified for natural gas and propane operation. UL listed. Meets all applicable safety standards. Copyright © Carrier Corporation. For support, visit www.carrier.com or contact 1-800-CARRIER.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Furnace won't start | Power/gas/thermostat | Check circuit breaker; verify gas supply; check thermostat settings. |
| No heat | Ignition/system lockout | Check for error codes; reset system; verify flame sensor operation. |
| Short cycling | Dirty filter/airflow | Replace air filter; check for blocked vents or registers. |
| Blower not running | Motor/control issue | Check for error codes; verify blower door switch operation. |
| Error codes displayed | System fault | Reference error code chart in service manual; contact technician if needed. |
Reset: Turn power off for 30 seconds then restore. Check error codes on Infinity control.
Service: 1-800-CARRIER; www.carrier.com