The Carrier 58STA090 is a high-efficiency gas furnace with 90% AFUE rating, featuring two-stage heating operation, variable-speed blower motor, durable heat exchanger construction, electronic ignition system, and comprehensive safety controls. Designed for residential heating applications with input capacity of 90,000 BTU/hr. Below are key sections for safety, features, installation, operation, maintenance, and troubleshooting.
Key components: Two-stage gas valve, variable-speed ECM blower motor, aluminized steel heat exchanger, hot surface igniter, pressure switches, flame sensor, and integrated control board.
| Feature | Description |
|---|---|
| AFUE Rating | 90% Annual Fuel Utilization Efficiency |
| Heating Stages | Two-stage operation for enhanced comfort |
| Blower Motor | Variable-speed ECM for quiet operation |
| Heat Exchanger | Aluminized steel construction |
| Ignition System | Hot surface electronic ignition |
| Gas Valve | Two-stage modulating gas valve |
| Control Board | Integrated furnace control |
| Pressure Switches | Draft and vent safety monitoring |
| Flame Sensor | Flame rectification safety |
| Filter System | Standard 1-inch filter slot |
Professional installation required. Verify local codes and obtain permits.
WARNING! Gas furnaces produce carbon monoxide; proper venting is critical. Installation must comply with all local codes.
Qualified technician must perform initial startup and commissioning.
CAUTION! Never attempt to adjust gas pressure without proper training and equipment.
Integrated furnace control board with status LED for diagnostics. Thermostat connections for conventional or advanced control systems.
Control Board: LED status light, dip switch settings for blower speeds, furnace configuration options.
Thermostat Wiring: R (24V power), W/W1/W2 (heat stages), G (fan), C (common), Y/Y1/Y2 (cooling stages if applicable).
DIP Switch Settings: Adjust blower speeds for heating and cooling modes, configure staging delays, set temperature rise parameters.
Follow wiring diagram provided with unit. All electrical work must comply with NEC and local codes.
Tip: Use wire nuts and electrical tape for all splices; keep wiring neat and organized.
Normal operation controlled by thermostat. Two-stage operation provides enhanced comfort.
WARNING! Never operate furnace with access panels removed or safety devices bypassed.
Regular maintenance ensures optimal performance and safety.
CAUTION! Turn off gas and electrical power before performing any maintenance.
Multiple safety systems protect against hazardous conditions: Flame rollout switches, high-limit switches, pressure switches, flame sensor, and ignition control safety timing.
UL listed and ANSI certified. Complies with U.S. Department of Energy efficiency standards. Manufactured to meet or exceed industry safety standards. For technical support, contact Carrier at 1-800-CARRIER or visit www.carrier.com.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Furnace won't start | Power, thermostat, safety lockout | Check disconnect switch, thermostat settings, reset if locked out. |
| No heat | Gas supply, ignition failure | Verify gas valve open, check for ignition attempts, inspect flame sensor. |
| Short cycling | Dirty filter, high limit | Replace air filter, check for restricted airflow, verify proper venting. |
| Blower not running | Motor, capacitor, control board | Check blower motor operation, test capacitor, verify control signals. |
| Lockout condition | Safety device tripped | Reset power, check error codes, identify tripped safety switch. |
Reset Procedure: Turn power off for 30 seconds, then restore power.
Service: 1-800-CARRIER; www.carrier.com