The Carrier Infinity 96 Furnace is a high-efficiency gas furnace featuring variable-speed technology, modulating gas valve, two-stage heating operation, advanced diagnostics, and compatibility with Carrier's Infinity System Control. With up to 96% AFUE efficiency, this furnace provides quiet, consistent heating with precise temperature control. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.
Key components: Variable-speed blower motor, modulating gas valve, two-stage heat exchanger, integrated control board, pressure switches, flame sensor, igniter, and diagnostic LED.
| Feature | Description |
|---|---|
| Variable-speed blower | Provides precise airflow control for optimal comfort and efficiency |
| Modulating gas valve | Adjusts gas flow from 40% to 100% capacity |
| Two-stage operation | Low and high fire stages for consistent temperature |
| Infinity System compatibility | Works with Carrier's advanced control system |
| Diagnostic LED | Displays error codes for troubleshooting |
| Pressure switches | Ensures proper venting operation |
| Flame sensor | Detects burner flame for safety |
| Hot surface igniter | Electronic ignition system |
| Condensate drain system | Removes condensation from high-efficiency operation |
| Multi-speed blower settings | Adjustable airflow for different applications |
Unpack and inspect all components. Ensure proper clearances and venting requirements.
WARNING! Gas furnaces produce carbon monoxide; ensure proper venting. Only qualified technicians should perform installation.
Power on furnace; follow startup sequence and verify proper operation.
CAUTION! Verify gas connections for leaks using bubble solution. Never use open flame to check for leaks.
Access control board via front panel. Diagnostic LED displays error codes. Infinity Control provides advanced system management.
Control Board: POWER switch, Diagnostic LED, DIP switches, terminal strip.
Heating Settings: Two-stage operation, blower speeds, temperature rise adjustment. Fan Settings: Continuous fan operation, timed off-delay. Safety Controls: Limit switches, pressure switches, flame rollout switches. Diagnostics: LED flash codes for troubleshooting, system status monitoring.
Gas supply: Black iron pipe with sediment trap. Electrical: 120V power, thermostat connections. Venting: PVC intake and exhaust. Drain: Condensate removal system.
Tip: Always use two wrenches when making gas connections to prevent twisting pipes.
Normal heating cycle operation and system sequencing.
WARNING! Never bypass safety controls. If furnace fails to operate properly, shut off power and gas, then call for service.
LED error codes: Flash patterns indicate specific issues. Infinity Control diagnostics: Advanced system monitoring and fault reporting.
| LED Flash Code | Description |
|---|---|
| 1 flash | Pressure switch stuck closed |
| 2 flashes | Pressure switch stuck open |
| 3 flashes | Limit circuit fault |
| 4 flashes | Ignition failure |
| 5 flashes | Flame sensed with gas valve off |
| 6 flashes | Blower fault |
| 7 flashes | Gas valve circuit fault |
Annual maintenance required for optimal performance and safety.
CAUTION! Turn off electrical power and gas supply before performing maintenance. Only qualified technicians should service gas components.
ANSI Z21.47: Certified for natural gas and LP operation. UL 795: Commercial-industrial gas heating equipment. Meets ASHRAE 90.1 energy efficiency standards. For technical support, contact Carrier Corporation at 1-800-CARRIER or visit www.carrier.com. Manufactured by Carrier Corporation, Farmington, CT.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Furnace won't start | Power, thermostat, door switch | Check circuit breaker, thermostat settings, door switch engagement |
| No heat | Gas supply, ignition | Verify gas valve on, check for spark/flame, inspect flame sensor |
| Short cycling | Dirty filter, airflow | Replace air filter, check for blocked vents/registers |
| Blower won't run | Motor, capacitor, control | Check blower motor, capacitor, control board signals |
| Error codes displayed | Safety lockout | Reset power, check LED code, refer to diagnostic chart |
| Unusual noises | Mechanical issues | Inspect blower wheel, motor bearings, heat exchanger |
Reset Procedure: Turn off power for 30 seconds, then restore power to reset control board.
Service: 1-800-CARRIER; www.carrier.com