Carrier Infinity 96 Furnace Service Manual

The Carrier Infinity 96 Furnace is a high-efficiency gas furnace featuring variable-speed technology, modulating gas valve, two-stage heating operation, advanced diagnostics, and compatibility with Carrier's Infinity System Control. With up to 96% AFUE efficiency, this furnace provides quiet, consistent heating with precise temperature control. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting Components 7. Operating Procedures 8. Diagnostic Features 9. Maintenance & Cleaning 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Variable-speed blower motor, modulating gas valve, two-stage heat exchanger, integrated control board, pressure switches, flame sensor, igniter, and diagnostic LED.

FeatureDescription
Variable-speed blowerProvides precise airflow control for optimal comfort and efficiency
Modulating gas valveAdjusts gas flow from 40% to 100% capacity
Two-stage operationLow and high fire stages for consistent temperature
Infinity System compatibilityWorks with Carrier's advanced control system
Diagnostic LEDDisplays error codes for troubleshooting
Pressure switchesEnsures proper venting operation
Flame sensorDetects burner flame for safety
Hot surface igniterElectronic ignition system
Condensate drain systemRemoves condensation from high-efficiency operation
Multi-speed blower settingsAdjustable airflow for different applications

Installation

Unpack and inspect all components. Ensure proper clearances and venting requirements.

  1. Position furnace: Place on stable, level surface with proper clearances (1-inch minimum from combustible materials).
  2. Install venting: Use approved PVC piping for intake and exhaust vents.
  3. Connect gas supply: Use black iron pipe with proper thread sealant.
  4. Electrical connections: Connect 120V power supply and thermostat wiring.
  5. Drain connections: Install condensate drain line with proper slope.

WARNING! Gas furnaces produce carbon monoxide; ensure proper venting. Only qualified technicians should perform installation.

First-Time Setup

Power on furnace; follow startup sequence and verify proper operation.

  1. Gas pressure adjustment: Set manifold pressure per specifications (3.5" WC natural gas).
  2. Blower speed settings: Configure cooling and heating speeds per application requirements.
  3. Thermostat configuration: Program Infinity Control for optimal operation.
  4. System checkout: Verify proper ignition sequence, flame detection, and safety controls.
  5. Combustion analysis: Measure flue gases for proper CO levels and efficiency.

CAUTION! Verify gas connections for leaks using bubble solution. Never use open flame to check for leaks.

Specifications

Controls and Settings

Access control board via front panel. Diagnostic LED displays error codes. Infinity Control provides advanced system management.

Control Board: POWER switch, Diagnostic LED, DIP switches, terminal strip.

Heating Settings: Two-stage operation, blower speeds, temperature rise adjustment. Fan Settings: Continuous fan operation, timed off-delay. Safety Controls: Limit switches, pressure switches, flame rollout switches. Diagnostics: LED flash codes for troubleshooting, system status monitoring.

Connecting Components

Gas supply: Black iron pipe with sediment trap. Electrical: 120V power, thermostat connections. Venting: PVC intake and exhaust. Drain: Condensate removal system.

  1. Turn off gas and electrical power before making connections.
  2. Use proper pipe size for gas supply (½-inch minimum).
  3. Ensure vent pipes slope back toward furnace for drainage.
  4. Verify thermostat wiring matches control board terminals.

Tip: Always use two wrenches when making gas connections to prevent twisting pipes.

Operating Procedures

Normal heating cycle operation and system sequencing.

  1. Call for heat: Thermostat signals furnace to begin heating cycle.
  2. Prepurging: Blower operates to clear combustion chamber.
  3. Ignition sequence: Hot surface igniter glows, gas valve opens.
  4. Flame establishment: Flame sensor confirms ignition.
  5. Heating operation: Modulating gas valve adjusts flame, blower circulates warm air.
  6. Shutdown: Gas valve closes, blower continues for post-purge cooling.
  7. Stage operation: System operates in low stage for mild weather, high stage for cold conditions.

WARNING! Never bypass safety controls. If furnace fails to operate properly, shut off power and gas, then call for service.

Diagnostic Features

LED error codes: Flash patterns indicate specific issues. Infinity Control diagnostics: Advanced system monitoring and fault reporting.

LED Flash CodeDescription
1 flashPressure switch stuck closed
2 flashesPressure switch stuck open
3 flashesLimit circuit fault
4 flashesIgnition failure
5 flashesFlame sensed with gas valve off
6 flashesBlower fault
7 flashesGas valve circuit fault

Maintenance & Cleaning

Annual maintenance required for optimal performance and safety.

  1. Clean or replace air filter monthly during heating season.
  2. Inspect burners and heat exchanger for corrosion or damage.
  3. Clean flame sensor with fine sandpaper or steel wool.
  4. Check condensate drain system for clogs.
  5. Verify vent system is clear and properly sloped.
  6. Lubricate blower motor if required (most ECM motors are sealed).

CAUTION! Turn off electrical power and gas supply before performing maintenance. Only qualified technicians should service gas components.

Regulatory Information

ANSI Z21.47: Certified for natural gas and LP operation. UL 795: Commercial-industrial gas heating equipment. Meets ASHRAE 90.1 energy efficiency standards. For technical support, contact Carrier Corporation at 1-800-CARRIER or visit www.carrier.com. Manufactured by Carrier Corporation, Farmington, CT.

Troubleshooting

SymptomPossible CauseCorrective Action
Furnace won't startPower, thermostat, door switchCheck circuit breaker, thermostat settings, door switch engagement
No heatGas supply, ignitionVerify gas valve on, check for spark/flame, inspect flame sensor
Short cyclingDirty filter, airflowReplace air filter, check for blocked vents/registers
Blower won't runMotor, capacitor, controlCheck blower motor, capacitor, control board signals
Error codes displayedSafety lockoutReset power, check LED code, refer to diagnostic chart
Unusual noisesMechanical issuesInspect blower wheel, motor bearings, heat exchanger

Reset Procedure: Turn off power for 30 seconds, then restore power to reset control board.

Service: 1-800-CARRIER; www.carrier.com