The Carrier Performance Series Furnace is a high-efficiency residential heating system featuring advanced variable-speed technology, quiet operation, and energy-saving performance. This gas furnace offers multiple stages of heating, durable construction, and smart diagnostic capabilities. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.
Key components: Variable-speed blower motor, two-stage gas valve, insulated cabinet, diagnostic LED, pressure switches, igniter, flame sensor.
| Feature | Description |
|---|---|
| Variable-speed motor | Provides precise airflow control and quiet operation |
| Two-stage heating | Offers high and low fire stages for comfort and efficiency |
| Insulated cabinet | Reduces operating noise |
| Diagnostic LED | Displays error codes for troubleshooting |
| Pressure switches | Ensures proper venting operation |
| Hot surface igniter | Reliable electronic ignition system |
| Flame sensor | Monitors burner operation for safety |
| Gas valve | Precise gas flow control |
| Blower compartment | Houses circulating air system |
| Filter rack | Standard 1-inch or 4-inch media filter compatible |
Unpack and inspect contents. Position in approved location with proper clearances.
WARNING! Installation must be performed by qualified HVAC technician. Follow all local codes and manufacturer instructions.
Power on furnace; follow startup sequence.
CAUTION! Never bypass safety controls. Ensure proper ventilation and combustion air supply.
Access control board via front panel. Integrated control module with diagnostic LED.
Thermostat: Compatible with single-stage, two-stage, and variable-speed thermostats.
Heating: Two-stage operation with automatic staging. Blower: Variable-speed control with multiple airflow settings. Diagnostics: LED flash codes for error identification. Safety: Pressure switches, flame rollout switch, high limit control. Settings: DIP switches for blower speed, gas type, thermostat compatibility.
Compatible with most 24V thermostats. Standard connections: R, C, W, Y, G.
Tip: Use thermostat with appropriate staging for optimal performance.
Automatic operation via thermostat control.
WARNING! Do not attempt to manually override safety controls. Contact professional service if issues occur.
Regular maintenance ensures optimal performance and longevity.
CAUTION! Always turn off power and gas supply before performing maintenance.
Turn off power before cleaning. Keep area around furnace clear and clean.
CAUTION! Do not use water or liquid cleaners on electrical components. Keep combustion air intake clear.
UL certified; meets ANSI Z21.47 standards. CSA certified for Canada. Complies with Department of Energy efficiency standards. Copyright © 2024 Carrier Corporation; all rights reserved. For support, visit www.carrier.com or contact 1-800-CARRIER.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Furnace won't start | Power, thermostat, door switch | Check circuit breaker, thermostat settings, ensure door closed properly. |
| No heat | Gas supply, igniter, flame sensor | Verify gas valve open, check for ignition attempts, clean flame sensor. |
| Short cycling | Filter, limit switch, airflow | Replace dirty filter, check for blocked vents, verify proper airflow. |
| Blower won't stop | Thermostat, control board | Check thermostat fan setting, inspect control board operation. |
| Error code flashing | Various system faults | Count LED flashes and refer to diagnostic chart in manual. |
Reset: Turn power off for 30 seconds, then restore.
Service: 1-800-CARRIER; www.carrier.com