Central Boiler Dual Fuel Outdoor Wood Furnace Owners Manual

The Central Boiler Dual Fuel Outdoor Wood Furnace is a high-efficiency heating system designed for outdoor installation that provides heat for residential and commercial applications. This dual-fuel system can burn wood as primary fuel with automatic switchover to backup fuel source (propane, natural gas, or oil). Features include thermal storage capacity, automatic draft control, corrosion-resistant construction, and compatibility with existing forced-air or hydronic heating systems. Below are key sections for safety, features, installation, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation Requirements 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Fuel System Operation 7. Maintenance Procedures 8. Safety Features 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Dual-fuel combustion chamber, Thermal storage tank, Automatic draft control, Heat exchanger, Water jacket, Backup fuel system, Control panel, Chimney system.

FeatureDescription
Dual-fuel capabilityPrimary wood burning with automatic backup fuel switchover
Thermal storageStores heat for consistent temperature control
Automatic draft controlRegulates airflow for optimal combustion efficiency
Corrosion-resistant constructionStainless steel or coated steel for durability
Water jacketTransfers heat to hydronic systems
Control panelDigital display with temperature and system status
Backup fuel systemPropane, natural gas, or oil backup
Chimney systemInsulated stainless steel chimney
Safety shutdownAutomatic shutdown in case of system faults
Expansion tank connectionFor hydronic system pressure management

Installation Requirements

Proper installation is critical for safety and performance. Follow all local codes and manufacturer specifications.

  1. Location: Install outdoors with proper clearances from structures (minimum 10 feet from buildings).
  2. Foundation: Level, non-combustible base (concrete pad recommended).
  3. Chimney: Install according to height requirements (minimum 2 feet above roof line).
  4. Water connections: Use approved piping materials for hydronic systems.
  5. Electrical: Grounded 120V AC power supply required.
  6. Fuel storage: Proper wood storage area; backup fuel tank installation as required.

WARNING! Installation must comply with local building codes and clearances. Professional installation recommended.

First-Time Setup

Complete system commissioning after installation.

  1. Fill water system: Check for leaks, fill with water/glycol mixture as specified.
  2. Prime pumps: Ensure circulation pumps are primed and operational.
  3. Set controls: Configure temperature settings and backup fuel parameters.
  4. Test operation: Verify proper wood combustion and backup fuel switchover.
  5. Check safety systems: Verify high-limit switches and pressure relief valves.

CAUTION! Never operate with empty water jacket. Ensure proper water chemistry to prevent corrosion.

Specifications

Controls and Settings

Digital control panel provides system monitoring and adjustment capabilities.

Control Panel: Power On/Off, Temperature Display, Set Temperature, Fuel Mode Selection, Pump Controls, Alarm Reset.

Temperature Settings: Supply temperature, Return temperature, Differential setting. Fuel Management: Wood mode, Backup fuel mode, Automatic switchover temperature. System Controls: Circulation pump operation, Draft control settings, Backup fuel activation temperature. Safety: High-limit temperature, Low-water cutoff, Pressure relief valve testing.

Fuel System Operation

Dual-fuel operation provides reliable heating with automatic backup.

  1. Wood burning: Load dry, seasoned wood (moisture content below 20%).
  2. Combustion control: Automatic draft regulates air supply for efficient burning.
  3. Backup activation: System automatically switches to backup fuel when wood fire diminishes.
  4. Fuel monitoring: Control panel indicates active fuel source and status.
  5. Efficiency tips: Use properly seasoned wood, maintain good air circulation around unit.

Tip: Regular chimney cleaning improves efficiency and reduces creosote buildup.

Maintenance Procedures

Regular maintenance ensures optimal performance and longevity.

  1. Daily: Check water pressure gauge, observe smoke quality.
  2. Weekly: Remove ash from firebox, check for creosote buildup.
  3. Monthly: Inspect chimney, check all connections, verify safety controls.
  4. Seasonal: Clean heat exchanger, inspect refractory, check water chemistry.
  5. Annual: Professional inspection of entire system, chimney cleaning.

WARNING! Always allow unit to cool completely before performing maintenance. Wear protective equipment.

Safety Features

Multiple safety systems protect against hazardous conditions.

Safety FeatureFunction
High-limit switchShuts down system if temperature exceeds safe limits
Pressure relief valveReleases pressure if system pressure becomes excessive
Low-water cutoffPrevents operation with insufficient water level
Draft safeguardEnsures proper chimney draft for safe combustion
Backup fuel monitoringAutomatic shutdown if backup fuel system fails

Regulatory Information

UL Certified to applicable safety standards. EPA Phase 2 qualified for emissions. Installation must comply with local building codes, fire codes, and environmental regulations. Copyright © Central Boiler. For technical support, visit www.centralboiler.com or contact 1-800-248-4681.

Troubleshooting

SymptomPossible CauseCorrective Action
No heat outputEmpty wood supply/fuel issueAdd wood, check backup fuel supply, verify pump operation
Poor combustionWet wood/chimney blockageUse dry wood, clean chimney, check draft control
Water pressure lowSystem leak/makeup water issueCheck for leaks, refill system, inspect pressure relief valve
Backup fuel not engagingControl setting/fuel supplyCheck control settings, verify backup fuel supply and ignition
Excessive smokePoor draft/wet woodClean chimney, use properly seasoned wood, check air controls

Reset: Control panel > System > Reset if alarm condition occurs.

Service: 1-800-248-4681; www.centralboiler.com