The Coleman Evcon Presidential Furnace is a high-efficiency gas furnace designed for residential heating applications. This manual covers the Presidential series models with features including variable-speed blower motors, electronic ignition systems, multiple heat stages, diagnostic LED indicators, and compatibility with standard thermostat controls. Below are key sections for safety, operation, maintenance, troubleshooting, and technical specifications.
Key components: Heat exchanger, blower assembly, gas valve, igniter, flame sensor, pressure switches, diagnostic board.
| Feature | Description |
|---|---|
| Variable-speed blower | Adjustable airflow for optimal efficiency and comfort |
| Electronic ignition | Hot surface igniter for reliable startup |
| Multi-stage heating | Multiple heat levels for temperature control |
| Diagnostic LED | Flash codes for troubleshooting |
| Pressure switches | Safety verification of venting system |
| Gas valve | Precise fuel control with safety shutoff |
| Flame sensor | Monitors burner operation |
| Filter access | Easy replacement of air filters |
| Limit switches | Over-temperature protection |
| Rollout switches | Flame rollout safety protection |
Professional installation recommended. Verify local codes and obtain permits.
WARNING! Gas appliances can be hazardous; installation must comply with all local codes and regulations. Only qualified technicians should perform installation.
Initial startup must be performed by qualified technician.
CAUTION! Never bypass safety controls. Ensure proper ventilation to prevent carbon monoxide buildup.
Integrated control board manages all furnace functions with diagnostic capabilities.
Control Board: POWER switch, Diagnostic LED, DIP switches for configuration.
Operation: Thermostat calls for heat > Inducer motor starts > Pressure switch proves > Hot surface igniter glows > Gas valve opens > Flame sensor confirms > Blower starts after heat exchanger warms.
Settings: Blower speed adjustments, heating stages, fan on/off delays, diagnostic modes.
Regular maintenance ensures optimal performance and safety.
Tip: Keep area around furnace clear of combustible materials and maintain proper airflow.
Compatible with standard 24V thermostats; advanced models support multi-stage and variable-speed controls.
WARNING! Always turn off power before working on thermostat wiring.
Multiple safety systems protect against hazardous conditions.
| Safety Device | Function |
|---|---|
| Limit switches | Shuts off burners if overheating detected |
| Pressure switches | Verifies proper venting before ignition |
| Flame rollout switches | Detects improper burner flames |
| Flame sensor | Confirms burner ignition; shuts off gas if no flame |
| Gas valve | Automatic shutoff in case of system fault |
Regular cleaning maintains efficiency and extends equipment life.
CAUTION! Always disconnect power before servicing. Never operate with access panels removed.
ANSI Z21.47: Certified for safety standards. UL listed. Meets DOE efficiency requirements. Manufactured to comply with U.S. safety and performance standards. For technical support, contact Coleman Heating & Air Conditioning at 1-800-426-5362 or visit www.colemanac.com. Serial number and model number located on rating plate inside unit.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Furnace won't start | Power, thermostat, safety lockout | Check power switch; verify thermostat setting; reset power; check diagnostic LED |
| No heat | Gas supply, igniter, flame sensor | Verify gas valve on; check for spark/glow; clean flame sensor |
| Short cycling | Dirty filter, blocked vent, limit switch | Replace filter; clear vents; check airflow; verify limit switch operation |
| Blower won't run | Motor, capacitor, control board | Check power to motor; test capacitor; verify control board signals |
| Unusual noises | Motor bearings, blower wheel, ductwork | Lubricate if applicable; tighten blower set screw; check for obstructions |
Diagnostic Codes: Refer to control board LED flash patterns for specific error codes.
Service: 1-800-426-5362; www.colemanac.com