The Coleman DGAA070BDTA is a 70,000 BTU gas furnace with upflow/horizontal airflow configuration, single-stage natural gas operation, multi-speed blower, electronic ignition, aluminized steel heat exchanger, and compatibility with standard thermostat controls. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.
Key components: Gas valve, inducer motor, heat exchanger, blower assembly, control board, pressure switches, flame sensor, igniter.
| Feature | Description |
|---|---|
| Heat Exchanger | Aluminized steel construction for durability |
| Blower Motor | Multi-speed ECM motor for efficient airflow |
| Ignition System | Hot surface igniter with flame sensor |
| Gas Valve | Single-stage natural gas operation |
| Airflow Configuration | Upflow/Horizontal compatible |
| Control Board | Integrated furnace controller with LED status lights |
| Pressure Switches | Safety switches for combustion air proving |
| Filter Rack | Standard 1-inch filter compatibility |
| Venting | Category I venting for natural draft |
| Thermostat Connection | Standard 24VAC thermostat terminals |
Unpack and inspect contents. Ensure proper location with adequate clearance.
WARNING! Gas appliances can be dangerous; installation must be performed by qualified technician. Ensure proper ventilation and combustion air.
Power on furnace; follow startup sequence.
CAUTION! Never bypass safety controls. Test all safety functions before regular operation.
Access control board via front panel. LED status lights indicate system operation.
Control Board: POWER ON/OFF switch, LED status indicator, thermostat terminals, pressure switch connections, gas valve control.
Blower Speed Settings: Adjust blower speed taps for proper airflow. Temperature Rise: Monitor and adjust to stay within 35-65°F range. Gas Pressure: Natural gas manifold pressure 3.5 inches w.c. Limit Controls: High limit switch for overheating protection. Pressure Switches: Prove inducer operation before gas valve opening.
Standard 24VAC thermostat connection with R, W, G, C terminals.
Tip: Use proper thermostat wire and ensure tight connections to prevent system faults.
Normal heating cycle operation sequence.
WARNING! Never operate furnace without proper venting and combustion air. Monitor for unusual noises or odors.
Regular maintenance ensures efficient and safe operation.
Turn off power and gas supply before cleaning. Use soft brush and vacuum for heat exchanger and blower assembly.
CAUTION! Do not use water or liquid cleaners. Keep electrical components dry. Never operate with dirty or clogged filter.
ANSI Z21.47: Certified for natural gas operation. UL listed. Must be installed in accordance with National Fuel Gas Code and local codes. For technical support, contact Coleman HVAC at 1-888-263-0540 or visit www.colemanac.com. Manufactured for residential use in the United States and Canada.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Furnace won't start | Power/thermostat | Check circuit breaker; verify thermostat setting and wiring. |
| No heat | Gas supply/ignition | Verify gas valve open; check for ignition failure; inspect flame sensor. |
| Short cycling | Dirty filter/overheating | Replace air filter; check for restricted airflow; verify proper temperature rise. |
| Blower won't run | Motor/control | Check blower capacitor; verify control board signals; inspect motor. |
| Lockout condition | Safety tripped | Reset power; check LED error codes; inspect pressure switches and limits. |
| Unusual noises | Mechanical issues | Inspect blower wheel; check inducer motor; verify proper clearances. |
Reset: Turn power off for 30 seconds then restore to reset control board.
Service: 1-888-263-0540; www.colemanac.com