The Comfortmaker Enviro Plus 90 is a high-efficiency gas furnace with 90% AFUE rating, featuring variable-speed blower motor, electronic ignition, multi-speed operation, and advanced diagnostic controls. Designed for residential heating applications with natural gas or propane capability. Below are key sections for safety, features, installation, operation, maintenance, and troubleshooting.
Key components: Heat exchanger, variable-speed blower motor, electronic ignition system, pressure switches, flame sensor, control board, gas valve, and diagnostic LED.
| Feature | Description |
|---|---|
| AFUE Rating | 90% Annual Fuel Utilization Efficiency |
| Blower Motor | Variable-speed ECM for efficient operation |
| Ignition System | Hot surface electronic ignition |
| Heat Exchanger | Stainless steel primary and secondary |
| Gas Type | Natural gas or propane (conversion kit required) |
| Control System | Integrated furnace control with diagnostics |
| Pressure Switches | Verify proper venting operation |
| Flame Sensor | Monitors burner flame presence |
| Filter System | Standard 1-inch or 4-inch media filter |
| Thermostat Connection | Standard 24VAC compatible |
Professional installation required. Ensure proper clearances and local code compliance.
WARNING! Gas appliances can be hazardous; installation must be performed by qualified technician. Carbon monoxide hazard exists with improper installation.
Initial startup must be performed by qualified technician.
CAUTION! Never bypass safety controls. Ensure proper combustion air supply.
Integrated control board with diagnostic LED. Access door switch for safety.
Control Board: LED status light (flash codes for diagnostics), DIP switches for configuration.
Thermostat Settings: Heat mode, fan auto/on, temperature setpoint. Blower Speeds: Multi-tap transformer for heating/cooling speeds. Gas Valve: Manual shutoff, pressure regulator. Limit Controls: High temperature safety, fan control limits.
Direct vent system using PVC pipes for intake and exhaust.
Tip: Vent pipes must be properly supported and sloped for condensation drainage.
Normal operation controlled by thermostat.
WARNING! Never operate furnace with access panels removed. Carbon monoxide poisoning hazard.
Regular maintenance required for optimal performance and safety.
CAUTION! Turn off power and gas supply before performing any maintenance.
Multiple safety systems protect against hazardous conditions.
| Safety Feature | Function |
|---|---|
| Flame Rollout Switch | Detects flame outside combustion chamber |
| High Limit Switch | Prevents overheating |
| Pressure Switches | Verify proper venting operation |
| Flame Sensor | Monitors burner flame presence |
| Ignition Control | Safe ignition sequence with trial for ignition |
| Door Switch | Shuts off unit when access panel is removed |
UL listed and ANSI certified. Complies with applicable safety standards. Manufactured to meet efficiency standards. For technical support, contact Comfortmaker at 1-800-772-9200 or visit www.comfortmaker.com. Installation must comply with local building codes and NFPA 54/National Fuel Gas Code.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Furnace won't start | Power, thermostat, door switch | Check power supply; verify thermostat setting; ensure door panel secure. |
| No heat | Gas supply, ignition | Verify gas valve on; check for ignition lockout; observe LED flash codes. |
| Blower won't run | Motor, capacitor, control | Check blower door switch; verify motor operation; inspect capacitor. |
| Short cycling | Filter, limit switch | Replace dirty filter; check for blocked vents; verify proper airflow. |
| Unusual noises | Blower, heat exchanger | Inspect blower wheel; check for loose components; examine heat exchanger. |
LED Codes: Refer to control board flash pattern for specific diagnostic information.
Service: 1-800-772-9200; www.comfortmaker.com