The Concord 90 Plus is a high-efficiency gas furnace with AFUE rating of 90% or higher, featuring electronic ignition, variable-speed blower motor, multi-speed operation, sealed combustion system, diagnostic LED indicator, built-in condensate removal system, and compatibility with standard thermostat controls. Designed for residential use with natural gas or propane capability. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.
Key components: Heat exchanger, blower assembly, gas valve, ignition system, pressure switches, flame sensor, condensate system, control board.
| Feature | Description |
|---|---|
| AFUE Rating | 90% or higher efficiency rating |
| Blower Motor | Variable-speed ECM motor for quiet operation |
| Ignition System | Hot surface ignition for reliable startup |
| Combustion System | Sealed combustion for safety and efficiency |
| Diagnostic LED | Flashing code indicator for troubleshooting |
| Gas Valve | Modulating valve for precise temperature control |
| Pressure Switches | Safety switches for combustion air verification |
| Flame Sensor | Monitors burner flame presence |
| Condensate System | Removes condensation from high-efficiency operation |
| Filter System | Standard 1-inch or 4-inch media filter capability |
Professional installation required. Verify local codes and obtain permits.
WARNING! Gas furnaces produce carbon monoxide; proper installation and venting critical for safety. Only qualified technicians should install.
Professional startup procedure required for proper operation.
CAUTION! Never bypass safety controls. Always verify proper operation before leaving installation.
Integrated control board manages all furnace functions with diagnostic capabilities.
Control Board: LED status light, dip switches for configuration, terminal strip for thermostat connection.
Operation Modes: Heating mode, fan continuous mode, diagnostic mode. Settings: Blower speed adjustments, timing delays, fault code reset. Safety Controls: Limit switches, pressure switches, flame rollout switches, ignitor control.
Compatible with standard 24V thermostats. Connection terminal designations: R, C, W, G, Y.
Tip: Use programmable thermostat for maximum efficiency and comfort.
Regular maintenance required for optimal performance and safety.
WARNING! Always turn off gas and electrical power before performing any maintenance.
Multiple safety systems protect against hazardous conditions: Flame rollout switches, high limit switches, pressure switches, ignitor safety lockout, condensate overflow switch.
Keep furnace area clean and clear of combustible materials. Regular filter changes essential.
CAUTION! Never store chemicals or flammable materials near furnace. Keep intake and exhaust vents clear of obstructions.
ANSI Z21.47/CSA 2.3 certified. UL listed. Meets DOE efficiency standards. Manufactured to comply with U.S. safety and efficiency regulations. For technical support, contact Concord HVAC at 1-800-555-HEAT or visit www.concordhvac.com.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Furnace won't start | Power, thermostat, safety lockout | Check power switch; verify thermostat setting; check diagnostic LED for fault code. |
| No heat | Gas supply, ignition, limit switch | Verify gas valve on; check for ignition attempts; reset limit switch if tripped. |
| Blower won't run | Motor, capacitor, control board | Check for power to blower; inspect capacitor; verify control board operation. |
| Frequent cycling | Filter, thermostat, limit switch | Replace dirty filter; check thermostat location; verify proper airflow. |
| Error codes flashing | Various fault conditions | Count LED flashes and refer to fault code chart in service manual. |
Reset: Power cycle furnace to clear temporary fault conditions.