The Daikin Furnace DC96VC is a high-efficiency gas furnace with variable-capacity operation, 96% AFUE rating, two-stage gas valve, variable-speed blower motor, durable heat exchanger, diagnostic LED system, and compatibility with Daikin thermostats. Designed for residential use with natural gas or propane, it requires professional installation. Below are key sections for safety, specifications, installation procedures, wiring, startup, and troubleshooting.
Critical safety information for installers and homeowners.
| Hazard | Precaution |
|---|---|
| Gas Leaks | Check all connections with leak detector; never use open flame |
| Electrical Shock | Disconnect power before servicing; follow local electrical codes |
| Carbon Monoxide | Ensure proper venting; install CO detectors in living areas |
| Fire Hazard | Maintain clearance from combustibles; install smoke detectors |
| Personal Injury | Wear safety glasses and gloves during installation |
Site preparation and necessary tools/materials.
WARNING! Installation must comply with local codes and regulations.
Step-by-step installation guide.
CAUTION! Use two people for lifting; unit is heavy.
Wiring connections and requirements.
| Connection | Specification |
|---|---|
| Power Supply | 115V, 60Hz, 15A circuit with disconnect |
| Thermostat | Standard 24V connections (R, W, Y, G, C) |
| Blower Motor | Variable-speed ECM motor |
| Control Board | Integrated diagnostic LED system |
| Grounding | Proper equipment grounding required |
Tip: Label all wires before disconnecting existing equipment.
Gas piping and pressure requirements.
WARNING! Gas line installation must be performed by qualified technician.
Intake and exhaust vent installation.
CAUTION! Do not use cellular core PVC; ensure proper support for long runs.
Initial system startup procedure.
Control settings and adjustments.
| Setting | Description |
|---|---|
| Blower Speed | Adjust for proper airflow (CFM settings) |
| Gas Pressure | Verify high and low fire settings |
| Thermostat Type | Compatible with single-stage and two-stage thermostats |
| Diagnostic Codes | LED flash patterns for troubleshooting |
| DIP Switches | Configuration for altitude, blower delay, etc. |
Routine maintenance schedule.
WARNING! Only qualified technicians should perform internal maintenance.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No heat | Power, thermostat, gas supply | Check circuit breaker, thermostat setting, gas valve |
| Furnace won't start | Door switch, pressure switch | Ensure doors closed; check pressure switch tubing |
| Short cycling | Dirty filter, airflow restriction | Replace filter; check for blocked vents/registers |
| Lockout mode | Ignition failure, flame sensor | Reset power; clean flame sensor; check gas pressure |
| Unusual noises | Blower, inducer motor | Inspect for obstructions; check motor bearings |
Reset: Turn power off for 30 seconds, then restore.
Service: Contact authorized Daikin dealer for technical support.