Day and Night Furnace Repair Manual

The Day and Night furnace is a high-efficiency heating system designed for residential and light commercial applications. This manual covers gas-fired forced air furnaces with AFUE ratings up to 96%, featuring electronic ignition, multi-speed blowers, safety controls, and compatibility with various thermostat systems. Below are key sections for safety procedures, technical specifications, installation guidelines, troubleshooting, maintenance, and repair instructions.

1. Safety Precautions 2. Model Identification 3. Technical Specifications 4. Installation Requirements 5. Electrical Connections 6. Gas Line Connections 7. Venting Systems 8. Startup and Commissioning 9. Operating Instructions 10. Maintenance Procedures 11. Troubleshooting Guide

Safety Precautions

Critical safety information for furnace installation, operation, and maintenance.

HazardPrecaution
Gas leaksCheck all connections with leak detection solution; never use open flame
Carbon monoxideEnsure proper venting; install CO detectors in living areas
Electrical shockDisconnect power before servicing; use lockout/tagout procedures
Hot surfacesAllow furnace to cool before handling internal components
Combustible materialsMaintain clearances per installation instructions

Model Identification

Locate model and serial numbers for proper parts identification and technical support.

  1. Model number: Found on rating plate inside furnace cabinet
  2. Serial number: Located adjacent to model number
  3. Manufacturing date: Encoded in serial number (first four digits)
  4. Technical specifications: Refer to model number for capacity and features

WARNING! Always provide complete model and serial numbers when ordering parts or seeking technical assistance.

Technical Specifications

Installation Requirements

Proper installation is critical for safe and efficient operation.

  1. Location: Install in areas with adequate combustion air and service access
  2. Clearances: Maintain minimum clearances to combustible materials
  3. Combustion air: Provide adequate fresh air per local codes
  4. Drain lines: Install condensate drain per instructions for high-efficiency models
  5. Venting: Install vent system according to furnace category and local codes

CAUTION! Installation must comply with all local codes and manufacturer specifications.

Electrical Connections

Wiring requirements and connection procedures.

ConnectionSpecification
Line voltage120V AC, 15 amp dedicated circuit
Thermostat24V AC; R, W, G, Y, C terminals
Blower speedsCooling, heating, continuous fan settings
Safety controlsLimit switches, pressure switches, rollout switches
Control boardIntegrated furnace controller with LED status lights

Gas Line Connections

Gas piping and connection requirements.

  1. Pipe sizing: Size gas line per local codes and furnace input requirements
  2. Shutoff valve: Install manual gas shutoff valve within 6 feet of furnace
  3. Drip leg: Install sediment trap ahead of gas control valve
  4. Pressure test: Test gas lines at maximum operating pressure
  5. Leak check: Test all connections with approved leak detection solution

WARNING! Gas connections must be made by qualified personnel only.

Venting Systems

Venting requirements based on furnace category.

Startup and Commissioning

Initial startup procedures and system verification.

  1. Verify all connections: Electrical, gas, venting, drain
  2. Check gas pressure: Manifold and inlet pressures
  3. Test safety controls: Verify proper operation of all safety devices
  4. Measure temperature rise: Ensure within specified range
  5. Check combustion: Use combustion analyzer for high-efficiency models
  6. Program thermostat: Set heating cycles and fan operation

NOTE: Complete startup checklist and leave with homeowner.

Operating Instructions

Normal operation and user controls.

ControlFunction
ThermostatSet desired temperature; system auto-cycles
System switchHeat, Off, Cool (if AC equipped)
Fan switchAuto or On for continuous circulation
LED status lightsFlash codes indicate system status
Reset buttonsManual reset for rollout or limit switches

Maintenance Procedures

Routine maintenance for optimal performance and longevity.

  1. Monthly: Check air filter; replace when dirty
  2. Seasonal: Inspect burners, heat exchanger, vent system
  3. Annual: Clean blower assembly and combustion chamber
  4. Biannual: Check gas pressure and combustion analysis
  5. As needed: Lubricate blower motor (if required)

CAUTION! Disconnect power and gas before performing maintenance.

Troubleshooting Guide

SymptomPossible CauseCorrective Action
No heatThermostat, power, gas valveCheck thermostat setting; verify power; check gas valve operation
Blower won't runMotor, capacitor, control boardTest motor windings; check capacitor; verify control signal
Short cyclingDirty filter, limit switchReplace filter; check limit switch operation; verify airflow
Ignition failureIgniter, flame sensor, gas pressureTest igniter continuity; clean flame sensor; check gas pressure
Unusual noisesBlower wheel, inducer motorInspect for debris; check motor bearings; tighten components
Error codesControl board diagnosticsInterpret LED flash codes; refer to diagnostic chart

Technical Support: 1-800-DAY-NIGHT; www.dayandnightfurnace.com

Emergency Service: Contact qualified HVAC technician for gas or electrical issues