Dayton Fuel Trimmer Furnace Manual

The Dayton Fuel Trimmer Furnace is a high-efficiency heating system designed for residential and light commercial use, featuring advanced fuel trimming technology, digital temperature controls, multiple heat settings, safety shut-off systems, and energy-saving modes. Below are key sections for safety, features, installation, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting to HVAC System 7. Operating Procedures 8. Safety Features 9. Maintenance & Cleaning 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Digital control panel, Fuel trimmer assembly, Heat exchanger, Blower motor, Safety sensors, Exhaust system.

FeatureDescription
Digital Control PanelLCD display with temperature settings and system status
Fuel Trimmer TechnologyOptimizes fuel consumption for maximum efficiency
Multiple Heat SettingsLow, Medium, High, and Auto modes
Safety Shut-off SystemAutomatic shut-off for overheating or pressure issues
Programmable Thermostat7-day programming capability
Blower MotorVariable speed for optimal airflow
Heat ExchangerStainless steel construction for durability
Exhaust VentPVC piping for efficient venting
Filter Access PanelEasy access for filter replacement
Power SwitchMain power control with safety lock

Installation

Unpack and inspect all components. Ensure proper clearance around unit.

  1. Position unit: Place on level surface with minimum 12-inch clearance on all sides.
  2. Connect fuel line: Use approved fuel piping; check for leaks with soap solution.
  3. Electrical connection: Connect to dedicated 120V circuit with proper grounding.
  4. Vent installation: Install PVC vent pipes according to local codes.
  5. Ductwork connection: Connect to existing HVAC duct system.

WARNING! Installation must be performed by qualified HVAC technician. Improper installation may cause fire hazard.

First-Time Setup

Power on furnace; follow initial setup procedure.

  1. System initialization: Allow 5-minute startup cycle for system calibration.
  2. Temperature calibration: Use CALIBRATE function in settings menu.
  3. Program schedule: Set daily temperature programs for energy savings.
  4. Test safety features: Verify shut-off systems are functioning properly.
  5. Fuel trimmer calibration: Run automatic fuel optimization cycle.

CAUTION! Do not bypass safety systems during setup. Keep area clear during initial operation.

Specifications

Controls and Settings

Access control panel via front door. Main controls: POWER, MODE, TEMP UP/DOWN, MENU, RESET.

Display Indicators: Current temp, Set temp, System status, Error codes, Filter reminder.

Settings Menu: Temperature calibration, Schedule programming, Fan control (Auto/On), System test, Fuel trimmer adjustment, Safety reset. Advanced settings: Service codes, Installation parameters, Diagnostic mode.

Connecting to HVAC System

Compatible with standard forced-air duct systems. Requires proper sizing and balancing.

  1. Turn off power to furnace and HVAC system.
  2. Connect supply plenum to furnace outlet using sheet metal screws.
  3. Connect return air duct to furnace intake.
  4. Seal all connections with approved duct sealant.
  5. Balance airflow by adjusting dampers if necessary.

Tip: Ensure ductwork is properly insulated and sealed for maximum efficiency.

Operating Procedures

Daily operation and special functions.

  1. Power on: Press POWER button; system will begin startup sequence.
  2. Set temperature: Use TEMP buttons or program schedule.
  3. Select mode: HEAT, FAN ONLY, or OFF.
  4. Fuel trimmer operation: Automatic adjustment for optimal efficiency.
  5. Fan control: AUTO (cycles with heat) or ON (continuous operation).
  6. Vacation mode: Reduces temperature when away for extended periods.
  7. System reset: Press RESET to clear error codes after addressing issue.

WARNING! Do not attempt to adjust fuel trimmer settings without proper training.

Safety Features

Multiple safety systems: High-limit switch, Flame rollout switch, Pressure switch, Ignition safety lockout, Overcurrent protection. All safety systems automatically shut down furnace and display error code.

Maintenance & Cleaning

Regular maintenance required for optimal performance and safety.

  1. Monthly: Check and replace air filter if dirty.
  2. Seasonal: Inspect burners and heat exchanger for debris.
  3. Annual: Professional inspection and cleaning recommended.
  4. Clean blower assembly and motor annually.
  5. Check vent system for obstructions.

CAUTION! Always turn off power and fuel supply before performing maintenance.

Regulatory Information

UL certified; meets ANSI Z21.47 standards for gas-fired central furnaces. CSA certified for Canadian market. EPA compliant for emissions. Copyright © Dayton Heating Systems. For technical support, visit www.daytonheating.com or contact 1-800-555-HEAT.

Troubleshooting

SymptomPossible CauseCorrective Action
Furnace won't startPower issue/thermostatCheck circuit breaker; verify thermostat settings; ensure door closed properly.
No heatFuel supply/ignitionCheck fuel valve; verify pilot/igniter operation; check error codes.
Insufficient heatFilter/airflowReplace air filter; check duct dampers; verify blower operation.
Frequent cyclingThermostat location/filterRelocate thermostat if near heat source; clean/replace filter.
Unusual noisesBlower/burnersInspect blower wheel; clean burners; check for loose components.
Error codes displayedSystem faultsRefer to error code chart in service manual; reset system after correction.

Reset Procedure: Power off for 30 seconds, then restart.

Service: 1-800-555-HEAT; www.daytonheating.com