Dayton Gas Furnace Manual

The Dayton Gas Furnace is a high-efficiency heating system designed for residential and light commercial use. This manual covers safety guidelines, installation procedures, operation instructions, maintenance requirements, and troubleshooting for various Dayton gas furnace models. Below are key sections for proper setup, operation, and maintenance of your heating system.

1. Safety Information 2. Installation Requirements 3. Technical Specifications 4. Operating Instructions 5. Control Settings 6. Maintenance Procedures 7. Venting Requirements 8. Gas Supply Connection 9. Electrical Wiring 10. Troubleshooting Guide 11. Warranty Information

Safety Information

Critical safety warnings and precautions for proper furnace operation.

WarningDescription
Carbon Monoxide HazardEnsure proper ventilation and regular inspection of heat exchanger
Gas LeaksCheck all gas connections with soap solution; never use open flame
Fire HazardKeep combustible materials away from furnace and vent pipes
Electrical SafetyDisconnect power before servicing; proper grounding required
Burn HazardAllow furnace to cool before servicing; surfaces remain hot after operation

Installation Requirements

Proper installation guidelines for safe and efficient operation.

  1. Location: Install in well-ventilated area with adequate clearance (minimum 18 inches from combustible materials).
  2. Combustion Air: Ensure adequate fresh air supply for proper combustion.
  3. Leveling: Place furnace on level surface to prevent stress on heat exchanger.
  4. Ductwork: Connect to properly sized and sealed duct system.
  5. Gas Line: Use approved black iron pipe with proper sizing for BTU input.

WARNING! Installation must comply with local codes and be performed by qualified technician.

Technical Specifications

Operating Instructions

Normal operation procedures and thermostat settings.

  1. Power On: Ensure gas valve and electrical power are turned on.
  2. Thermostat: Set to HEAT mode and desired temperature.
  3. Startup: Furnace will initiate pre-purge, ignition sequence, and main burner operation.
  4. Normal Operation: Blower will start after heat exchanger reaches temperature.
  5. Shutdown: Thermostat satisfied - gas valve closes, blower continues for cool-down.

Note: Allow 5-minute time delay between cycles for system protection.

Control Settings

Furnace control board settings and diagnostic indicators.

Control Board: LED status lights for diagnostics, DIP switch settings for blower speeds, gas type selection.

Thermostat Connections: R (24V), W (Heat), G (Fan), C (Common), Y (Cooling). Blower Speeds: Adjust DIP switches for heating and cooling CFM requirements. Pressure Switch: Monitors venting operation. Flame Sensor: Detects burner ignition. Limit Switches: High temperature safety cut-off.

Maintenance Procedures

Regular maintenance schedule for optimal performance and safety.

  1. Monthly: Check air filter; replace when dirty.
  2. Seasonal: Inspect burners, heat exchanger, and venting system.
  3. Annual: Professional inspection including gas pressure, combustion analysis, and safety controls.
  4. Blower Maintenance: Clean blower wheel and housing annually.
  5. Drain System: For condensing models, check condensate drain and trap.

Important: Only qualified technicians should perform internal maintenance.

Venting Requirements

Proper venting installation for safe combustion gas removal.

Gas Supply Connection

Gas line installation and pressure requirements.

  1. Pipe Sizing: Consult local codes and BTU requirements for proper diameter.
  2. Shut-off Valve: Install approved gas cock within 6 feet of furnace.
  3. Sediment Trap: Install drip leg before gas connection.
  4. Pressure Test: Test all connections with soap solution; check for leaks.
  5. Manifold Pressure: Adjust gas valve to specified pressure for your model.

WARNING! Gas work must be performed by licensed professional.

Electrical Wiring

Electrical connections and circuit requirements.

ConnectionRequirement
Power Supply120V, 60Hz, dedicated 15 Amp circuit
GroundingProper equipment grounding required
Thermostat18 gauge minimum, 5-conductor recommended
DisconnectInstall service switch within sight of furnace
Blower MotorFollow wiring diagram for proper speed taps

Troubleshooting Guide

Common issues and diagnostic procedures.

SymptomPossible CauseCorrective Action
No heatPower outage, thermostat setting, gas valveCheck power, thermostat, gas supply, and control board status lights
Furnace short cyclesDirty filter, restricted airflow, high limitReplace filter, check ductwork, verify proper airflow
Blower doesn't runMotor capacitor, control board, wiringCheck capacitor, control signals, and motor windings
Burner won't igniteGas supply, igniter, pressure switchVerify gas pressure, check hot surface igniter, test pressure switch
Unusual noisesBlower wheel, inducer motor, ductworkInspect for obstructions, loose components, or vibration

Reset Procedure: Turn power off for 30 seconds, then restore.

Warranty Information

Warranty coverage and registration details.

Standard warranty includes 20-year heat exchanger limited warranty, 5-year parts warranty, and 1-year labor warranty. Warranty registration required within 60 days of installation. Keep original sales receipt and installation date. For warranty service, contact authorized Dayton service provider. Proof of professional installation required for all warranty claims.

Customer Service: 1-888-DAYTON1; www.dayton.com