The DC90 Ultra High Efficiency Furnace is a high-performance gas furnace with 90% AFUE rating, variable-speed blower motor, two-stage gas valve, electronic ignition system, durable heat exchanger, smart thermostat compatibility, built-in diagnostic system, safety controls, and energy-efficient operation. Suitable for residential heating applications with natural gas or propane capability. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.
Key components: Two-stage gas valve, variable-speed ECM blower motor, aluminized steel heat exchanger, electronic ignition, pressure switches, flame sensor, diagnostic LED, filter access door.
| Feature | Description |
|---|---|
| AFUE Rating | 90% Annual Fuel Utilization Efficiency |
| Gas Valve | Two-stage operation for efficient heating |
| Blower Motor | Variable-speed ECM for quiet operation |
| Heat Exchanger | Aluminized steel construction |
| Ignition System | Electronic hot surface ignition |
| Diagnostic LED | Flash codes for troubleshooting |
| Filter Access | Front-loading filter compartment |
| Pressure Switches | Safety verification of vent operation |
| Flame Sensor | Monitors burner operation |
| Thermostat Compatibility | Works with most 24V thermostats |
Unpack and inspect all components. Ensure proper clearances and venting.
WARNING! Installation must be performed by qualified HVAC technician. Gas leaks can cause explosion or fire.
Power on furnace; follow startup procedure.
CAUTION! Never bypass safety controls. Ensure proper ventilation during operation.
Access control board via front panel. Diagnostic LED provides status codes.
Control Board: POWER switch, FUSE, THERMOSTAT terminals, GAS VALVE terminals, PRESSURE SWITCH terminals.
Operating Modes: HEAT, OFF, FAN ON. Blower Settings: Adjustable delay timers for fan on/off. Diagnostic Codes: LED flash patterns indicate specific faults. Gas Valve: Two-stage operation for high/low fire modes.
Compatible with most 24V thermostats. Standard 5-wire connection.
Tip: Use programmable thermostat for maximum energy efficiency.
Three main operating modes controlled by thermostat.
WARNING! Do not operate furnace without proper venting and air filters installed.
Regular maintenance ensures optimal performance and longevity.
CAUTION! Always turn off power and gas supply before performing maintenance.
Multiple safety systems protect against hazardous conditions.
| Safety Feature | Function |
|---|---|
| Flame Rollout Switch | Detects improper burner flames |
| High Limit Switch | Prevents overheating |
| Pressure Switches | Verify proper vent operation |
| Flame Sensor | Confirms burner ignition |
| Gas Valve | Automatic shutoff if flame not detected |
UL certified for safety standards. ANSI Z21.47 compliant for gas appliances. Meets DOE energy efficiency requirements. Manufactured to ISO 9001 quality standards. For technical support, contact 1-800-HEATING or visit www.dc90furnace.com. Serial number located on rating plate inside unit.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Furnace won't start | Power, thermostat, door switch | Check circuit breaker, thermostat settings, door switch engagement |
| No heat | Gas supply, ignition | Verify gas valve open, check for ignition attempts |
| Blower won't run | Motor, capacitor, wiring | Check blower motor, capacitor, electrical connections |
| Short cycling | Filter, limit switch | Replace dirty filter, check high limit switch |
| Lockout mode | Safety device tripped | Reset power, check diagnostic LED for fault code |
Reset Procedure: Turn power off for 30 seconds, then restore.
Service: 1-800-HEATING; www.dc90furnace.com