The DM 80 HS is a high-efficiency gas furnace with 80% AFUE rating, featuring variable-speed blower motor, electronic ignition, multi-speed operation, built-in diagnostic system, safety controls, and compatibility with standard thermostat systems. Designed for residential heating applications with natural gas or propane capability. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.
Key components: Heat exchanger, blower assembly, gas valve, electronic ignition, pressure switches, limit controls, diagnostic LED.
| Feature | Description |
|---|---|
| Heat Exchanger | Stainless steel construction for durability and efficiency |
| Blower Motor | Variable-speed ECM motor for quiet operation |
| Electronic Ignition | Hot surface igniter for reliable startup |
| Gas Valve | Modulating valve for precise gas flow control |
| Pressure Switches | Safety switches for combustion air verification |
| Limit Controls | High-temperature safety cutoff |
| Diagnostic LED | Flash codes for system status and error reporting |
| Filter Access | Front-loading standard 1-inch filter |
| Venting | PVC pipe compatible for sidewall or roof venting |
| Electrical | 120V AC, 60Hz standard connection |
Professional installation recommended. Ensure proper clearances and venting.
WARNING! Gas appliances can be hazardous; installation must comply with local codes and be performed by qualified technician.
After installation, perform initial startup procedure.
CAUTION! Never bypass safety controls. Ensure proper ventilation during operation.
Integrated control board manages all furnace functions with diagnostic capabilities.
Thermostat Control: Compatible with most 24V thermostats; heat/cool/fan modes.
Operation Sequence: Thermostat call for heat → inducer motor starts → pressure switch verification → hot surface igniter heats → gas valve opens → flame sensor verification → blower starts after heat exchanger warm-up.
Diagnostic LED: Green = normal operation; Flash codes indicate specific faults (refer to troubleshooting chart).
Standard 5-wire thermostat connection (R, W, Y, G, C).
Tip: Use programmable thermostat for optimal efficiency and comfort.
Regular maintenance ensures optimal performance and longevity.
WARNING! Always disconnect power before performing any maintenance.
Multiple safety systems protect against hazardous conditions.
Keep furnace area clean and unobstructed.
Exterior: Wipe with dry cloth; avoid water or cleaning chemicals.
Interior: Professional cleaning only; do not attempt to clean heat exchanger or burners.
Filter: Replace every 1-3 months depending on usage and air quality.
CAUTION! Never operate without filter installed. Keep combustible materials away from furnace.
Certified to ANSI Z21.47 standards for gas-fired central furnaces. CSA International certified. Meets U.S. Department of Energy efficiency standards. For technical support, contact 1-800-555-HEAT or visit www.dmfurnace.com. Serial number located on rating plate inside furnace door.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Furnace won't start | Power, thermostat, door switch | Check circuit breaker; verify thermostat setting; ensure door properly closed. |
| No heat | Gas supply, ignition, filter | Verify gas valve open; check for flash codes; replace dirty filter. |
| Short cycling | Filter, limit switch, airflow | Clean/replace filter; check for blocked vents; verify proper airflow. |
| Blower won't stop | Thermostat, control board | Check thermostat fan setting; may indicate control board issue. |
| Unusual noises | Motor, blower wheel, ductwork | Inspect for loose components; clean blower wheel; check duct connections. |
| Error codes flashing | Various system faults | Count flashes and refer to diagnostic chart in service manual. |
Reset: Turn power off for 30 seconds, then restore.
Service: 1-800-555-HEAT; www.dmfurnace.com