DM80HS Furnace Manual

The DM80HS is a high-efficiency gas furnace with 80% AFUE rating, featuring variable-speed blower motor, electronic ignition, multi-speed operation, durable heat exchanger, integrated control board, safety shutoff switches, filter access, and compatibility with standard thermostat systems. Designed for residential heating applications with natural gas or propane capability. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting Thermostat 7. Operation 8. Safety Features 9. Maintenance & Cleaning 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: High-efficiency heat exchanger, variable-speed blower, electronic ignition system, integrated control board, filter compartment, gas valve, pressure switches, flame sensor.

FeatureDescription
Heat ExchangerDurable stainless steel construction
Blower MotorVariable-speed ECM for efficient operation
Ignition SystemElectronic hot surface ignition
Control BoardIntegrated microprocessor control
Filter AccessFront-loading filter compartment
Gas ValveAutomatic gas flow regulation
Pressure SwitchesSafety verification of venting
Flame SensorMonitors burner flame presence
Limit SwitchesPrevents overheating
Drain ConnectionCondensate removal system

Installation

Unpack and inspect contents. Position in approved location with proper clearances.

  1. Gas connection: Use approved black iron pipe with pipe dope; pressure test for leaks.
  2. Electrical connection: Connect to 120V AC power with proper grounding.
  3. Vent system: Install PVC vent pipes per local codes with proper slope.
  4. Drain line: Connect condensate drain to approved disposal.
  5. Thermostat: Connect low-voltage wiring to control board.

WARNING! Gas appliances require professional installation. Ensure proper ventilation and combustion air supply.

First-Time Setup

Power on furnace; follow startup sequence.

  1. System check: Control board performs self-diagnostic test.
  2. Gas pressure: Verify correct manifold pressure per specifications.
  3. Blower speed: Set appropriate CFM for heating application.
  4. Thermostat configuration: Program heating cycles and temperature settings.
  5. Safety verification: Test limit switches and pressure controls.

CAUTION! Only qualified technicians should perform initial setup and adjustment.

Specifications

Controls and Settings

Access control board via front panel. LED status lights indicate system operation.

Control Board: POWER, STATUS LED, DIP switches for blower speed, gas type selection, thermostat configuration.

Heating: Temperature rise adjustment, blower on/off delays, cycle rate. Safety: Limit switch settings, pressure switch verification, flame sensor monitoring. Diagnostic: Error code display, system status indicators, reset function.

Connecting Thermostat

Standard 24V thermostat connection with R, W, G, C terminals.

  1. Turn off power to furnace before wiring.
  2. Connect thermostat wires to control board terminals.
  3. Match wire colors: R (24V), W (heat), G (fan), C (common).
  4. Program thermostat for heating operation.

Tip: Use programmable thermostat for optimal efficiency and comfort.

Operation

Automatic heating cycle controlled by thermostat.

  1. Call for heat: Thermostat signals control board.
  2. Pre-purge: Blower runs to clear combustion chamber.
  3. Ignition: Hot surface igniter glows, gas valve opens.
  4. Flame verification: Flame sensor confirms ignition.
  5. Heating: Burners operate, blower circulates warm air.
  6. Shutdown: Thermostat satisfied, gas valve closes, blower continues for post-purge.

WARNING! Never block air vents or returns. Maintain proper airflow.

Safety Features

Multiple safety systems: Flame rollout switches, high limit switches, pressure switches, flame sensor, ignition control lockout.

Maintenance & Cleaning

Annual professional maintenance recommended. Monthly filter inspection/replacement.

  1. Filter: Replace every 1-3 months depending on usage.
  2. Burners: Clean annually to ensure proper combustion.
  3. Flame sensor: Clean with emery cloth annually.
  4. Drain system: Flush condensate trap and lines.
  5. Blower: Vacuum and inspect for debris.

CAUTION! Turn off power and gas supply before performing any maintenance.

Regulatory Information

ANSI Z21.47: Certified for natural gas and propane operation. UL listed. Meets national fuel gas code requirements. For support, contact manufacturer technical service or authorized dealers. Installation must comply with local building codes and utility requirements.

Troubleshooting

SymptomPossible CauseCorrective Action
Furnace won't startPower, thermostat, safety switchCheck power supply; verify thermostat setting; reset door switch.
No heatGas supply, ignition, filterVerify gas valve on; check for ignition; replace dirty filter.
Short cyclingDirty filter, limit switchReplace filter; check for blocked vents; verify limit operation.
Blower won't stopThermostat, control boardCheck thermostat fan setting; inspect control board relay.
Error code flashingSystem faultRefer to error code chart in manual; reset if applicable.

Reset: Power cycle furnace; wait 5 minutes before restoring power.

Service: Contact qualified HVAC technician for all repairs.