The Ducane CMPE100U4 is a high-efficiency gas furnace with 100,000 BTU input capacity, 80% AFUE rating, single-stage operation, natural gas compatibility, electronic ignition, multi-speed blower motor, durable heat exchanger, and safety features including flame rollout and limit switches. Designed for residential heating applications with standard 120V AC power requirement. Below are key sections for safety, features, installation, operation, maintenance, and troubleshooting.
Key components: Gas valve, burners, heat exchanger, blower assembly, filter rack, control board, pressure switches, flame sensor, igniter.
| Feature | Description |
|---|---|
| Gas valve | Regulates natural gas flow to burners |
| Heat exchanger | Stainless steel primary and secondary heat exchangers |
| Blower assembly | Multi-speed ECM motor for air circulation |
| Filter rack | Standard 1-inch filter slot |
| Control board | Integrated furnace controller with LED status lights |
| Pressure switches | Verify proper venting operation |
| Flame sensor | Detects burner flame presence |
| Hot surface igniter | Electronic ignition system |
| Limit switches | Prevent overheating |
| Flame rollout switches | Safety shutoff for flame abnormalities |
Unpack and inspect all components. Ensure proper location and clearances.
WARNING! Gas furnaces produce carbon monoxide; proper venting is critical. Installation must comply with local codes and be performed by qualified technician.
Complete installation verification before initial startup.
CAUTION! Never bypass safety controls. Test all safety devices before placing in service.
Integrated control board manages all furnace functions with LED status indicator.
Operation Sequence: Thermostat call for heat → inducer motor starts → pressure switch verification → hot surface igniter energizes → gas valve opens → flame establishment → blower starts after heat exchanger warm-up.
Status Lights: Green - normal operation; Red flashing - fault condition (refer to fault code chart). Gas Valve: Single-stage operation. Blower Control: Automatic delay on start and stop. Limit Controls: Auto-reset high temperature limits.
Compatible with standard 24V thermostats. Terminal designations: R (24V), W (Heat), G (Fan), C (Common).
Tip: Use 18-gauge thermostat wire for runs under 50 feet.
Regular maintenance ensures optimal performance and safety.
WARNING! Gas furnace maintenance should be performed by qualified technicians only.
Multiple safety systems protect against hazardous conditions: Flame rollout switches, high limit switches, pressure switches, flame sensor, igniter control, gas valve safety shutoff.
Turn off power and gas supply before cleaning. Use soft brush and vacuum for dust removal.
CAUTION! Never use water or liquid cleaners on electrical components. Keep combustion area clear of debris.
ANSI Z21.47/CSA 2.3: Certified for natural gas operation. UL listed. Installation must comply with National Fuel Gas Code NFPA 54 and local building codes. For technical support, contact Ducane HVAC at 1-800-338-0525 or visit www.ducanehvac.com.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Furnace won't start | Power, thermostat, door switch | Check circuit breaker, thermostat setting, door switch engagement |
| No heat | Gas supply, igniter, flame sensor | Verify gas valve on, check igniter operation, clean flame sensor |
| Short cycling | Filter, limit switch, airflow | Replace filter, check limit switch, verify proper airflow |
| Blower won't stop | Thermostat, control board | Check thermostat fan setting, control board operation |
| Lockout condition | Safety device activation | Reset power, check fault code, inspect safety controls |
Reset Procedure: Turn power off for 30 seconds then restore.
Service: 1-800-338-0525; www.ducanehvac.com