The Ducane MPGA100B4A is a high-efficiency gas furnace with 100,000 BTU input capacity, single-stage operation, multi-speed blower, and AFUE rating up to 80%. Features include hot surface ignition, induced draft combustion, safety controls, and compatibility with standard thermostats. Below are key sections for safety, features, installation, operation, maintenance, and troubleshooting.
Key components: Gas valve, burners, heat exchanger, blower assembly, induced draft motor, control board, pressure switches, and safety controls.
| Feature | Description |
|---|---|
| Input Capacity | 100,000 BTU/hour |
| AFUE Rating | Up to 80% efficiency |
| Gas Type | Natural gas (convertible to LP) |
| Ignition System | Hot surface ignition |
| Venting | PVC or ABS plastic pipe |
| Blower Type | Multi-speed PSC motor |
| Control System | Integrated furnace control board |
| Safety Features | Flame rollout, limit switches, pressure switches |
| Dimensions | Standard upflow configuration |
| Warranty | Limited lifetime heat exchanger |
Professional installation required. Verify local codes and obtain permits.
WARNING! Gas appliances can produce carbon monoxide. Proper installation and venting are critical for safety.
Initial startup must be performed by qualified technician.
CAUTION! Never bypass safety controls. Test for gas leaks before operation.
Integrated control board manages ignition sequence, blower operation, and safety monitoring.
Operation Sequence: Thermostat call for heat → Inducer motor starts → Pressure switch proves draft → Hot surface ignition → Gas valve opens → Flame sensed → Blower starts after delay.
Status Lights: Control board LED indicates normal operation or fault codes.
Thermostat: Compatible with standard 24V heating thermostats; programmable models recommended for efficiency.
24V thermostat connections: R (power), W (heat), G (fan), C (common).
Tip: Label all wires before disconnecting for easy reassembly.
Annual maintenance by qualified technician recommended.
WARNING! Turn off gas and electrical power before performing maintenance.
Flame rollout switch: Detects burner flame outside combustion area. Limit switches: Prevent overheating. Pressure switches: Verify proper venting draft. Thermal fuse: Additional overheating protection.
Keep area around furnace clean and free of combustible materials. Clean exterior with damp cloth only.
CAUTION! Do not use water or cleaning solutions on electrical components. Keep filters clean for proper airflow.
ANSI Z21.47/CSA 2.3: Certified for US and Canada. UL listed. Must be installed in accordance with National Fuel Gas Code and local codes. For support, contact Ducane HVAC at 1-800-338-0525 or visit www.ducanehvac.com.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Furnace won't start | Power, thermostat, door switch | Check circuit breaker, thermostat setting, door switch engagement |
| No heat | Gas supply, ignition | Verify gas valve on, check for ignition attempts, inspect flame sensor |
| Short cycling | Dirty filter, airflow | Replace filter, check for blocked vents, verify proper temperature rise |
| Blower won't run | Motor, capacitor, control | Check for power to blower, test capacitor, verify control board output |
| Lockout mode | Safety switch, flame | Reset power, check fault code, inspect safety controls and flame sensor |
Reset: Turn power off for 30 seconds then restore.
Service: 1-800-338-0525; www.ducanehvac.com