The Ducane Model PGA100B4 is a high-efficiency gas furnace designed for residential heating applications. This 100,000 BTU unit features a multi-speed blower, electronic ignition, and safety controls. Below are key sections for safety, features, installation, operation, maintenance, and troubleshooting.
Key components: Gas valve, heat exchanger, blower assembly, electronic ignition, pressure switches, limit controls.
| Feature | Description |
|---|---|
| Input Capacity | 100,000 BTU/h |
| Efficiency | 80% AFUE |
| Blower Type | Multi-speed direct drive |
| Ignition System | Hot surface electronic ignition |
| Gas Type | Natural gas |
| Venting | Category I vertical or horizontal |
| Electrical | 115V, 60Hz |
| Dimensions | See specifications section |
| Safety Controls | Flame rollout, limit switches, pressure switches |
| Warranty | 20-year heat exchanger, 5-year parts |
Professional installation required. Verify local codes and obtain permits.
WARNING! Gas furnaces produce carbon monoxide. Proper installation and venting are critical for safety.
After installation, perform initial startup procedure.
CAUTION! Only qualified HVAC technicians should perform startup procedures.
Integrated control board manages all furnace operations with LED status indicators.
Control Board: Monitors safety devices, controls ignition sequence, manages blower operation.
Thermostat Connections: R, W, G, Y, C terminals. Blower Speeds: Adjustable for heating and cooling modes. Limit Switches: High temperature protection. Pressure Switches: Verify proper venting. Gas Valve: Regulates gas flow with manual shutoff.
Proper venting is essential for safe operation.
Tip: Inspect vent system annually for obstructions or deterioration.
Normal operation controlled by thermostat.
WARNING! Never operate furnace with access panels removed.
Annual professional maintenance recommended.
CAUTION! Turn off power and gas before performing any maintenance.
Multiple safety devices protect against hazardous conditions.
| Safety Device | Function |
|---|---|
| Flame Rollout Switch | Detects flame outside combustion chamber |
| High Limit Switch | Shuts off gas if temperatures exceed safe limits |
| Pressure Switch | Verifies proper venting before ignition |
| Flame Sensor | Confirms flame presence during operation |
| Gas Valve | Automatic shutoff if ignition fails |
ANSI Z21.47: Certified for natural gas operation. UL Listed: Meets safety standards. Installation must comply with National Fuel Gas Code NFPA 54 and local building codes. For technical support, contact Ducane at 1-800-338-0070 or visit www.ducanehvac.com.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Furnace won't start | Power, thermostat, safety lockout | Check power switch, thermostat setting, reset furnace |
| No heat | Gas supply, ignition failure | Verify gas valve on, check for ignition attempts |
| Short cycling | Dirty filter, limit switch | Replace air filter, check for restricted airflow |
| Blower won't stop | Thermostat setting, control board | Check thermostat fan setting, inspect control board |
| Unusual noises | Loose components, airflow | Inspect blower wheel, check ductwork for restrictions |
Reset Procedure: Turn power off for 30 seconds, then restore power.
Service: 1-800-338-0070; www.ducanehvac.com