The Empire Floor Furnace is a high-efficiency gas heating system designed for residential floor installation, featuring natural gas/LPG compatibility, electronic ignition, adjustable thermostat control, safety shut-off valves, heat exchanger technology, and durable steel construction. Below are key sections for safety, features, installation, operation, maintenance, and troubleshooting.
Key components: Steel heat exchanger, electronic ignition system, adjustable thermostat, safety shut-off valve, floor vent, gas connection port, pilot light assembly.
| Feature | Description |
|---|---|
| Heat Exchanger | Durable steel construction for efficient heat transfer |
| Electronic Ignition | Automatic spark ignition system |
| Adjustable Thermostat | Precise temperature control |
| Safety Shut-off Valve | Automatic gas shut-off in case of malfunction |
| Floor Vent | Distributes warm air evenly throughout room |
| Gas Connection Port | For natural gas or LPG supply line |
| Pilot Light Assembly | Standing pilot with viewing window |
| Temperature Control | Manual dial for heat output adjustment |
| Pressure Regulator | Maintains consistent gas pressure |
| Ventilation System | Ensures proper combustion air flow |
Unpack and inspect contents. Ensure proper floor clearance and ventilation.
WARNING! Installation must be performed by qualified technician. Improper installation can cause fire, explosion, or carbon monoxide poisoning.
Initial startup and safety checks.
CAUTION! Never attempt to repair gas components yourself. Always use certified technicians.
Main control panel includes thermostat dial, pilot control knob, and main gas valve.
Operation: Turn thermostat to desired temperature, system automatically ignites and maintains heat.
Temperature Settings: Adjustable from 60°F to 85°F. Pilot Light: Follow lighting instructions precisely. Gas Valve: Main shut-off for complete gas flow control. Thermostat: Maintains consistent room temperature automatically.
Proper gas line installation is critical for safe operation.
Tip: Always install a manual shut-off valve within 6 feet of furnace for emergency use.
Daily operation and seasonal startup.
WARNING! If you smell gas, immediately turn off gas supply, evacuate area, and call gas company or fire department.
Thermal overload protection, flame failure device, pressure regulator, automatic shut-off valve. Carbon monoxide detector recommended for installation area.
Annual professional inspection recommended. Clean burner assembly, check heat exchanger, inspect vent system.
CAUTION! Never operate furnace without proper ventilation. Keep combustible materials away from unit.
ANSI Z21 standards compliance. UL listed. Local building codes may apply. Installation must meet NFPA 54 requirements. For technical support, contact Empire Heating Systems at 1-800-EMP-FURN or visit www.empireheating.com.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Furnace won't ignite | Gas supply/pilot | Check gas valve; relight pilot; ensure thermostat calling for heat. |
| Insufficient heat | Air flow/thermostat | Clean filters; check vent obstruction; verify thermostat setting. |
| Pilot won't stay lit | Thermocouple | Replace thermocouple; clean pilot assembly. |
| Gas odor | Leak | Immediately shut off gas; evacuate; call professional. |
| Unusual noises | Expansion/air flow | Check for loose components; ensure proper ventilation. |
Reset: Turn thermostat to lowest setting, wait 5 minutes, restart.
Service: 1-800-EMP-FURN; www.empireheating.com