The Fahrenheit 50 Pellet Furnace is a high-efficiency heating system designed for residential use, featuring automatic pellet feed, digital thermostat control, ash removal system, safety sensors, and energy-saving modes. With a heating capacity of up to 50,000 BTU/hr, this furnace operates on wood pellets and includes features such as programmable timers, temperature settings, maintenance alerts, and compatibility with standard venting systems. Below are key sections for safety, features, installation, operation, maintenance, and troubleshooting.
Key components: Digital control panel, pellet hopper, combustion chamber, ash drawer, exhaust vent, safety sensors, and thermostat connection.
| Feature | Description |
|---|---|
| Digital Control Panel | For temperature settings, timer, and mode selection |
| Pellet Hopper | Holds up to 40 lbs of wood pellets |
| Combustion Chamber | High-efficiency burn system with ceramic lining |
| Ash Drawer | Easy-remove container for ash disposal |
| Exhaust Vent | Standard 3-inch vent for smoke output |
| Safety Sensors | Overheat protection and low pellet detection |
| Thermostat Connection | Compatible with standard home thermostats |
| Power Switch | Turns furnace on/off |
| Mode Selector | Auto, Manual, and Economy modes |
| Maintenance Alert | LED indicator for cleaning and service needs |
Unpack and inspect contents. Place on level, non-combustible surface.
WARNING! Furnace must be installed by qualified technician. Ensure proper venting to prevent carbon monoxide buildup.
Power on furnace; follow startup sequence.
CAUTION! Do not block air intakes or exhaust. Keep children and pets away during operation.
Access settings via digital control panel. Buttons: POWER, MODE, TEMP UP/DOWN, TIMER, IGNITE, RESET.
Remote Thermostat: Set temperature; furnace responds automatically in AUTO mode.
Modes: AUTO (thermostat-controlled), MANUAL (constant burn), ECONOMY (reduced pellet feed). Settings: Temperature range 60°F–85°F, timer programs, maintenance alerts. Safety: Overheat shutdown, low pellet sensor, flame-out protection.
Use only premium wood pellets; avoid wet or contaminated fuel.
Tip: Store pellets in dry area to prevent moisture damage.
Supports continuous heating with automatic pellet feed.
WARNING! Never use gasoline or accelerants. Do not open combustion chamber during operation.
Regular cleaning ensures efficiency and safety.
CAUTION! Always turn off and unplug before maintenance. Wear gloves when handling ash.
Overheat Protection: Shuts down if temperature exceeds safe limits. Low Pellet Sensor: Alerts when fuel is low. Flame-Out Protection: Stops pellet feed if flame extinguishes. Carbon Monoxide Detector: Compatible with external CO alarms.
UL Certified: Meets safety standards for residential heating appliances. EPA Phase II: Compliant with emission requirements. Copyright © 2025 Fahrenheit Heating Systems; trademarks of Fahrenheit Inc. For support, visit www.fahrenheitheating.com or contact 1-800-555-HEAT.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No ignition | Empty hopper/wet pellets | Refill with dry pellets; check ignition element. |
| Low heat output | Dirty burn pot/airflow | Clean burn pot; ensure vents are clear. |
| Furnace shuts off | Overheat/blocked vent | Check for obstructions; allow cool-down. |
| Ash buildup | Full ash drawer | Empty drawer; clean combustion area. |
| Error code on display | Sensor fault | Refer to code chart in manual; reset if needed. |
Reset: Press RESET button on control panel.
Service: 1-800-555-HEAT; www.fahrenheitheating.com