The Fisher Scientific Isotemp Muffle Furnace 550 Series is a high-performance laboratory furnace designed for applications requiring precise temperature control up to 1100°C. Features include digital temperature control, programmable settings, ceramic fiber insulation, over-temperature protection, and durable stainless steel construction. Below are key sections for safety, features, installation, operation, maintenance, and troubleshooting.
Key components: Digital temperature controller, ceramic heating chamber, stainless steel exterior, safety door interlock, overtemperature protection.
| Feature | Description |
|---|---|
| Temperature Range | Ambient to 1100°C |
| Controller Type | Digital PID with LED display |
| Chamber Material | Ceramic fiber insulation |
| Exterior Construction | Stainless steel |
| Safety Features | Door interlock, overtemperature protection |
| Power Requirements | 120V/240V AC, 50/60Hz |
| Chamber Dimensions | Various sizes available |
| Programmability | Multi-segment temperature programming |
| Certifications | CE, UL, cUL listed |
| Warranty | 1-year limited warranty |
Unpack and inspect contents. Place on stable, level surface away from flammable materials.
WARNING! Furnace reaches extremely high temperatures; install away from combustible materials. Ensure proper ventilation.
Power on furnace; follow initial setup procedure.
CAUTION! Wear appropriate personal protective equipment (PPE) when operating furnace.
Access control panel via front digital display and keypad.
Control Panel: POWER, SET, UP/DOWN arrows, ENTER, PROGRAM, START/STOP.
Temperature Settings: Set point temperature, ramp rate, hold time. Safety: Overtemperature protection set point, door interlock. Programming: Multi-segment programs with ramp and soak capabilities. Display: Current temperature, set point, program status, error codes.
Standard operating procedure for sample processing.
WARNING! Do not open door during high-temperature operation. Always use thermal protection when handling hot materials.
Regular maintenance ensures optimal performance and longevity.
CAUTION! Always disconnect power before performing maintenance. Allow furnace to cool completely before cleaning.
Multiple safety systems protect users and equipment.
Complies with UL Standard 3101-1, CSA C22.2 No. 1010.1, and CE directives for laboratory equipment. Manufactured under ISO 9001 quality system. Copyright © Fisher Scientific. For technical support, contact Fisher Scientific Customer Service at 1-800-766-7000 or visit www.fishersci.com.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Furnace won't heat | Power supply, heating elements | Check power connection; verify circuit breaker; inspect heating elements. |
| Temperature inaccurate | Calibration, thermocouple | Recalibrate temperature; check thermocouple connection. |
| Error code displayed | Overtemperature, sensor fault | Refer to error code table in manual; reset if safe. |
| Door won't lock | Interlock mechanism | Check door alignment; inspect interlock switch. |
| Excessive exterior heat | Insulation, ventilation | Ensure proper clearance; check insulation integrity. |
Reset: Power cycle unit; clear error codes from control panel.
Service: 1-800-766-7000; www.fishersci.com