Fisher Scientific Isotemp Muffle Furnace Manual

The Fisher Scientific Isotemp Muffle Furnace is a high-temperature laboratory furnace designed for applications such as ashing, heat treatment, and materials testing. It features precise temperature control, durable ceramic interior, digital display, safety interlocks, and programmable temperature settings. Operating temperature range up to 1100°C (2012°F) with uniform heating. Below are key sections for safety, features, installation, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Operating Procedures 7. Maintenance 8. Safety Features 9. Care & Cleaning 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Ceramic chamber, Digital temperature controller, Heating elements, Door safety switch, Power cord, Ventilation ports.

FeatureDescription
Ceramic chamberHigh-temperature resistant interior for uniform heating
Digital temperature controllerPrecise temperature setting and monitoring
Heating elementsRapid heating to maximum temperature
Door safety switchAutomatically cuts power when door is opened
Power cordFor electrical connection
Ventilation portsPrevents overheating during operation
Temperature displayShows set and actual temperature
Programmable settingsAllows for temperature ramping and hold times
Over-temperature protectionPrevents exceeding safe operating limits
Power switchTurns furnace on/off

Installation

Unpack and inspect contents. Place on stable, heat-resistant surface.

  1. Location: Install in well-ventilated area away from flammable materials.
  2. Electrical connection: Connect to appropriate power supply (check voltage requirements).
  3. Grounding: Ensure proper grounding for safety.
  4. Clearance: Maintain minimum 6-inch clearance on all sides.

WARNING! Furnace reaches extremely high temperatures; install away from combustible materials. Ensure proper ventilation.

First-Time Setup

Power on furnace; follow initial setup procedure.

  1. Initial burn-off: Run empty at 400°C for 2 hours to remove manufacturing residues.
  2. Temperature calibration: Verify temperature accuracy with calibrated thermometer.
  3. Program settings: Set default temperature parameters if programmable.
  4. Safety check: Test door safety switch and over-temperature protection.

CAUTION! Wear heat-resistant gloves during initial setup. Do not touch hot surfaces.

Specifications

Controls and Settings

Access control panel for temperature programming and monitoring.

Control Panel: POWER, Temperature setpoint, Program buttons, Display, Alarm indicators.

Temperature Settings: Setpoint adjustment, Ramp rate, Hold time, Soak duration. Safety: Over-temperature protection, Door interlock, Power failure recovery. Programming: Multi-segment programs, Temperature profiles, Memory storage.

Operating Procedures

Standard operating sequence for sample processing.

  1. Preparation: Load samples using ceramic crucibles or boats.
  2. Programming: Set desired temperature profile.
  3. Start cycle: Close door securely and start program.
  4. Monitoring: Observe temperature display during operation.
  5. Completion: Allow furnace to cool before opening door.
  6. Removal: Use tongs to remove hot samples.

Tip: Always pre-heat furnace to desired temperature before loading samples for consistent results.

Maintenance

Regular maintenance ensures optimal performance and longevity.

  1. Monthly: Inspect heating elements for damage.
  2. Quarterly: Clean chamber interior with soft brush.
  3. Annually: Calibrate temperature controller.
  4. As needed: Replace worn components.

WARNING! Always disconnect power before performing maintenance. Allow furnace to cool completely.

Safety Features

Multiple safety systems protect users and equipment.

FeatureFunction
Door safety interlockCuts power when door opens
Over-temperature protectionPrevents exceeding set limits
Ground fault protectionElectrical safety
Thermal insulationReduces exterior temperature
Alarm systemAudible/visual warnings for faults

Care & Cleaning

Disconnect power and allow to cool completely before cleaning.

  1. Interior: Use soft brush to remove debris from chamber.
  2. Exterior: Wipe with damp cloth; avoid harsh chemicals.
  3. Heating elements: Inspect for oxidation or damage.
  4. Ventilation: Keep ports clear of obstructions.

CAUTION! Never use water or liquid cleaners on hot surfaces. Wear protective equipment.

Regulatory Information

UL 3101-1: Laboratory electrical equipment safety standards. CE Marking: Complies with European safety standards. Copyright © 2025 Fisher Scientific; trademarks of Thermo Fisher Scientific. For technical support, visit www.fishersci.com or contact 1-800-766-7000.

Troubleshooting

SymptomPossible CauseCorrective Action
Furnace not heatingPower supply/elementsCheck power connection; inspect heating elements; verify settings.
Temperature inaccurateCalibration/controllerRecalibrate temperature sensor; check controller settings.
Door won't close properlyObstruction/latchClear chamber obstructions; inspect door latch mechanism.
Error codes displayedSystem faultsRefer to error code chart in manual; reset if applicable.
OverheatingVentilation/controllerEnsure adequate ventilation; check over-temperature protection.

Reset: Power cycle unit; reset controller to factory defaults if needed.

Service: 1-800-766-7000; www.fishersci.com

Fisher Scientific Isotemp Muffle Furnace Manual © - All Rights Reserved 2025