The Ruud Furnace Achiever 90 Plus is a high-efficiency gas furnace with advanced flame sensor technology that ensures safe and reliable operation. The flame sensor detects the presence of a flame during ignition and continuously monitors it during operation to prevent gas leaks and ensure proper combustion. Below are key sections covering safety, features, installation, maintenance, troubleshooting, and replacement procedures for the flame sensor system.
The flame sensor is a critical safety component that detects flame presence using a rod that generates microamp current when heated by the burner flame. This signal confirms proper ignition and allows the gas valve to remain open.
| Component | Description |
|---|---|
| Flame Sensor Rod | Stainless steel rod positioned in flame path |
| Mounting Bracket | Secures sensor to burner assembly |
| Electrical Connector | 2-pin connector to control board |
| Sensor Cable | Insulated wiring to main control board |
| Cleaning Access | Removable for maintenance without disassembly |
Always follow safety protocols when working with furnace components.
WARNING! Failure to follow safety procedures may result in fire, explosion, or carbon monoxide poisoning. Only qualified technicians should perform flame sensor maintenance.
Proper installation ensures reliable flame detection and furnace operation.
CAUTION! Incorrect sensor positioning may cause false flame detection or failure to detect flame.
The flame sensor works in conjunction with the ignition control system during each heating cycle.
Normal Operation Sequence: Gas valve opens > igniter heats > spark ignition > flame sensor detects flame > control board confirms flame > system continues operation.
If flame is not detected within 4-7 seconds, control board closes gas valve and enters lockout mode after 3 attempts.
Regular maintenance prevents flame sensor failure and ensures reliable operation.
Tip: Schedule maintenance before heating season for optimal performance.
Cleaning removes carbon buildup that can interfere with flame detection.
WARNING! Do not use abrasive materials that may scratch sensor surface. Avoid touching cleaned surface with bare hands.
Replace flame sensor if cleaning doesn't restore proper operation or if physical damage is present.
CAUTION! Use only manufacturer-approved replacement parts to maintain safety and warranty coverage.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Furnace short cycles | Dirty flame sensor | Clean sensor with emery cloth |
| No ignition lockout | Failed sensor | Test microamp reading; replace if below 1 μA |
| Intermittent operation | Loose connection | Check wiring and connectors |
| False flame detection | Sensor grounding | Check insulation and mounting |
| Error code flashing | Sensor circuit fault | Diagnose control board and wiring |
Flame sensor meets UL 795 and ANSI Z21.47 standards for commercial and industrial gas-fired appliances. Certified for use with natural gas and propane systems. Complies with NFPA 54 National Fuel Gas Code requirements for flame safeguard systems.
The Ruud Achiever 90 Plus control board displays error codes related to flame sensor issues:
Service: Contact Ruud certified technician at 1-800-722-2704 or visit www.ruud.com