Furnace Carbolite CWF 1300 Operation Manual PDF

The Carbolite CWF 1300 is a high-temperature chamber furnace designed for laboratory and industrial applications, featuring a maximum operating temperature of 1300°C, digital PID temperature controller, ceramic fiber insulation, programmable temperature profiles, over-temperature protection, and durable stainless steel construction. Below are key sections for safety, features, installation, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Operating Procedures 7. Temperature Programming 8. Safety Features 9. Maintenance & Cleaning 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: High-temperature chamber, Digital PID controller, Ceramic heating elements, Thermal insulation, Over-temperature protection, Chamber door with safety interlock.

FeatureDescription
Maximum Temperature1300°C (2372°F)
Chamber DimensionsCustomizable based on model variant
Temperature ControllerDigital PID with programmable profiles
Heating ElementsSilicon carbide or molybdenum disilicide
InsulationCeramic fiber for high efficiency
Safety FeaturesOver-temperature protection, door interlock
Power Requirements208-240V AC, single or three phase
Data InterfaceRS232/RS485 for data logging
ConstructionStainless steel exterior
CertificationsCE, UL standards compliance

Installation

Unpack and inspect contents. Place on stable, level surface.

  1. Location: Install in well-ventilated area with adequate clearance from combustible materials.
  2. Electrical Connection: Connect to appropriate power supply (208-240V AC) using qualified electrician.
  3. Ventilation: Ensure adequate room ventilation or connect to exhaust system if required.
  4. Grounding: Verify proper grounding according to local electrical codes.

WARNING! Furnace operates at extremely high temperatures; maintain safe clearance from walls and flammable materials. Use heat-resistant gloves when handling hot components.

First-Time Setup

Power on furnace; follow initial setup procedure.

  1. Initial Burn-off: Run furnace empty at 1000°C for 2 hours to remove manufacturing residues.
  2. Controller Setup: Set temperature units (°C/°F), date/time, and safety parameters.
  3. Calibration: Verify temperature calibration using reference thermocouple if required.
  4. Test Run: Program simple temperature ramp and verify proper operation.

CAUTION! Always wear appropriate personal protective equipment (PPE) including heat-resistant gloves and safety glasses.

Specifications

Controls and Settings

Access control via front panel interface. Main Controls: POWER, TEMPERATURE SET, PROGRAM, START/STOP.

Controller Functions: Temperature display, Setpoint adjustment, Program editing, Ramp/soak programming, Alarm settings, PID tuning.

Temperature Settings: Setpoint, Ramp rate, Soak time, Program segments. Safety: Over-temperature protection setpoint, Door interlock, Power failure recovery. System: Language, Temperature units, Date/time, Calibration offsets.

Operating Procedures

Standard operation for heat treatment processes.

  1. Preparation: Load samples ensuring adequate clearance from heating elements.
  2. Program Selection: Choose pre-set program or create new temperature profile.
  3. Start Cycle: Close door securely, press START to begin heating cycle.
  4. Monitoring: Observe temperature display and program progress.
  5. Completion: Allow furnace to cool naturally or use controlled cooling program.
  6. Unloading: Wear heat-resistant gloves, open door carefully, remove samples.

Tip: Always allow furnace to cool below 100°C before opening door for extended periods.

Temperature Programming

Supports complex ramp/soak programs with up to 30 segments.

  1. Access Program Mode: Press PROGRAM button on controller.
  2. Segment Setup: For each segment, set target temperature, ramp rate, and soak time.
  3. Program Storage: Save program to memory for future use.
  4. Program Execution: Select program and press START to run.
  5. Pause/Resume: Use HOLD function to temporarily pause program.
  6. Program Editing: Modify existing programs or create new ones as needed.

WARNING! Do not exceed maximum temperature rating. Monitor program execution closely during initial runs.

Safety Features

Over-temperature Protection: Independent safety controller with separate thermocouple. Door Interlock: Prevents operation when door is open. Power Failure Protection: Program memory retention and safe recovery options.

Maintenance & Cleaning

Disconnect power before maintenance. Allow furnace to cool completely before cleaning.

  1. Chamber Cleaning: Remove debris with soft brush or vacuum with HEPA filter.
  2. Element Inspection: Check heating elements for damage or sagging monthly.
  3. Thermocouple: Verify calibration every 6 months or as required.
  4. Exterior: Wipe with damp cloth; avoid abrasive cleaners.

CAUTION! Never use compressed air for cleaning as it can damage insulation and heating elements.

Regulatory Information

CE Compliant: Meets European safety standards. UL Standards: Complies with applicable UL standards for laboratory equipment. Copyright © Carbolite Gero Ltd. All rights reserved. For technical support, visit www.carbolite-gero.com or contact +44 (0) 1433 620011.

Troubleshooting

SymptomPossible CauseCorrective Action
Furnace not heatingPower supply/elementsCheck power connection; verify heating elements; check fuses.
Temperature inaccurateThermocouple/calibrationVerify thermocouple connection; recalibrate controller.
Error messagesController faultsRefer to error code in manual; reset controller if safe.
Door won't closeInterlock mechanismCheck door alignment; verify interlock switch operation.
Over-temperature tripSafety controllerReset over-temperature protection; verify setpoints.

Reset: Controller menu > System > Reset to factory defaults if required.

Service: +44 (0) 1433 620011; www.carbolite-gero.com

Furnace Carbolite CWF 1300 Operation Manual © - All Rights Reserved 2025