The Furnace C23-41W-1 is a high-efficiency gas furnace with 23,000 BTU output, 41,000 BTU input capacity, AFUE rating of 95%, single-stage operation, electronic ignition, variable-speed blower motor, multi-speed settings, built-in diagnostic system, safety shut-off features, and compatibility with standard thermostat systems. Designed for residential use with natural gas or propane (with conversion kit). Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.
Key components: Gas valve assembly, heat exchanger, blower motor, electronic control board, pressure switches, flame sensor, igniter, filter compartment.
| Feature | Description |
|---|---|
| Gas valve | Controls gas flow to burners with safety shut-off |
| Heat exchanger | Stainless steel primary and secondary heat exchangers |
| Blower motor | Variable-speed ECM motor with multi-speed settings |
| Control board | Microprocessor-based with diagnostic LED |
| Pressure switches | Verify proper venting operation |
| Flame sensor | Detects burner flame for safety |
| Hot surface igniter | Electronic ignition system |
| Filter access | Front-loading filter compartment |
| Vent connections | PVC pipe connections for intake and exhaust |
| Electrical connections | 120V AC power and thermostat terminals |
Unpack and inspect contents. Install in approved location with proper clearances.
WARNING! Gas appliances can be dangerous; installation must be performed by qualified technician. Ensure proper ventilation and combustion air supply.
Power on furnace; follow startup sequence.
CAUTION! Never bypass safety controls. Carbon monoxide hazard exists if improperly installed.
Access control board via front panel. Diagnostic LED: Flashing codes indicate system status.
Thermostat Settings: HEAT/COOL/OFF, FAN AUTO/ON, temperature setpoint.
Blower Speeds: Cooling (high), heating (medium-high), continuous fan (low). Gas Valve: Single-stage operation. Control Board: Self-diagnostic with error codes, lockout protection, status LED. Safety Controls: Limit switches, pressure switches, flame rollout switch, flame sensor.
Standard 5-wire thermostat connection: R (24V power), W (heat), G (fan), Y (cool), C (common).
Tip: Use programmable thermostat for optimal efficiency and comfort.
Normal heating operation sequence:
WARNING! Never operate without filter. Keep combustible materials away from furnace.
Monthly: Check filter, clean if reusable. Annually: Professional inspection and cleaning.
Professional maintenance should include: Clean burners and heat exchanger, check gas pressure, inspect flame sensor and igniter, verify safety controls, check vent system, lubricate motor if required, check electrical connections.
Turn off power before servicing. Replace filter every 1-3 months. Keep area around furnace clean and unobstructed.
CAUTION! Do not use compressed air to clean interior; can damage components. Only qualified technicians should service gas and electrical components.
ANSI Z21.47: Certified for natural gas operation. CSA International: Certified to applicable standards. UL listed components. For natural gas use only unless converted for propane. Installation must comply with local building codes and NFPA 54. For support, contact manufacturer at 1-800-555-HEAT or visit www.furnacemanufacturer.com.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No heat | Thermostat setting, power, gas supply | Check thermostat setting, circuit breaker, gas valve position. |
| Furnace not starting | Limit switch, pressure switch | Check filter, vent pipes, reset by power cycling. |
| Blower not running | Motor, capacitor, control board | Check for loose wires, blown fuse, motor capacitor. |
| Short cycling | Dirty filter, blocked vent | Replace filter, check vent pipes for obstruction. |
| Lockout mode | Failed ignition, flame loss | Check gas supply, igniter, flame sensor; power cycle to reset. |
Reset: Turn power off for 30 seconds, then restore.
Service: 1-800-555-HEAT; www.furnacemanufacturer.com