The TG9S060B12MP11 is a high-efficiency gas furnace with 60,000 BTU input capacity, 96% AFUE rating, single-stage operation, multi-speed blower motor, electronic ignition, aluminized steel heat exchanger, LED status indicator, and compatibility with standard thermostat systems. Designed for residential use with natural gas, this furnace features safety controls, diagnostic capabilities, and easy maintenance access. Below are key sections for safety, features, installation, operation, maintenance, and troubleshooting.
Key components: Aluminized steel heat exchanger, multi-speed blower motor, electronic ignition system, LED status light, gas valve, pressure switches, flame sensor, and filter access panel.
| Feature | Description |
|---|---|
| Heat Exchanger | Aluminized steel construction for durability and efficiency |
| Blower Motor | Multi-speed ECM motor for optimized airflow |
| Ignition System | Electronic hot surface ignition |
| LED Status Light | Diagnostic indicator for troubleshooting |
| Gas Valve | Single-stage natural gas operation |
| Pressure Switches | Safety controls for venting system |
| Flame Sensor | Monitors burner operation |
| Filter Access | Easy-access panel for filter replacement |
| AFUE Rating | 96% Annual Fuel Utilization Efficiency |
| Input Capacity | 60,000 BTU/hour |
Professional installation required. Verify local codes and obtain permits.
WARNING! Gas furnace installation must be performed by qualified technician. Improper installation can cause fire, explosion, or carbon monoxide poisoning.
After installation, perform initial startup procedure.
CAUTION! Never operate furnace without proper venting and air filter installed.
Integrated control board with diagnostic LED. Access via control panel.
Control Board: LED status light (flashing codes for diagnostics), dip switch settings for blower speeds, system configuration.
Thermostat Connections: Standard 24V connections (R, W, G, Y, C). Blower Settings: Adjustable speeds for heating and continuous fan operation. Safety Controls: Pressure switches, flame rollout switch, high limit switch. Diagnostic Codes: LED flash patterns indicate specific fault conditions.
Compatible with standard 24V thermostats. Professional installation recommended.
Tip: Use programmable thermostat for optimal efficiency and comfort.
Normal heating operation controlled by thermostat.
WARNING! If you smell gas, immediately turn off gas supply, evacuate area, and call gas company.
Regular maintenance ensures optimal performance and safety.
CAUTION! Only qualified technicians should perform internal maintenance.
Keep furnace area clean and unobstructed.
Exterior: Wipe with dry cloth. Do not use water or cleaning solutions. Air Filter: Replace every 1-3 months depending on usage. Venting: Keep intake and exhaust pipes clear of debris. Combustion Area: Professional cleaning only.
CAUTION! Never spray liquids into furnace. Keep flammable materials away from unit.
ANSI Z21.47: Certified for natural gas operation. UL listed. Complies with U.S. energy efficiency standards. Manufactured to meet industry safety standards. For technical support, contact manufacturer or authorized service provider.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Furnace won't start | Power, thermostat, switch | Check power supply; verify thermostat setting; check door switch. |
| No heat | Gas supply, filter, ignition | Verify gas valve on; check/replace filter; check for ignition lockout. |
| Short cycling | Filter, limit switch | Replace dirty filter; check for blocked vents or registers. |
| Blower won't stop | Thermostat setting | Check thermostat fan setting (Auto vs On). |
| Unusual noises | Motor, blower wheel | Check for loose components; professional inspection needed. |
| LED error code | System fault | Refer to diagnostic chart in service manual. |
Reset: Turn power off for 30 seconds, then restore. If problem persists, call for service.
Service: Contact qualified HVAC technician for all repairs.