Gaffers and Sattler U100 Furnace Manual

The Gaffers and Sattler U100 Furnace is a high-efficiency residential heating unit with 80,000 BTU output, electronic ignition, variable-speed blower motor, multi-position installation capability, digital thermostat compatibility, safety shutoff features, and energy-saving operation modes. Designed for natural gas operation with optional LP conversion kit. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation Requirements 3. Initial Setup and Startup 4. Technical Specifications 5. Controls and Operation 6. Maintenance Procedures 7. Safety Features 8. Thermostat Configuration 9. Seasonal Maintenance 10. Regulatory Compliance 11. Troubleshooting Guide

Features at a Glance

Key components: Stainless steel heat exchanger, electronic ignition system, variable-speed blower motor, multi-position flue, integrated control board, pressure switches, flame sensor, and diagnostic LED.

FeatureDescription
Heat ExchangerStainless steel construction for durability and efficiency
Ignition SystemElectronic hot surface ignition
Blower MotorVariable-speed ECM for quiet operation
Installation PositionsUpflow, downflow, horizontal left, horizontal right
Control BoardIntegrated microprocessor with diagnostic capabilities
Flue OptionsPVC or ABS venting for sidewall or roof termination
Gas ValveModulating for precise temperature control
Filter SizeStandard 16x25x1 inch filter
Safety FeaturesFlame rollout switch, pressure switches, high limit control
Diagnostic LEDFlashing codes for troubleshooting

Installation Requirements

Proper installation is critical for safe and efficient operation. Follow all local codes and manufacturer specifications.

  1. Location: Install in well-ventilated area with adequate clearance (minimum 24 inches front, 6 inches sides)
  2. Gas Connection: Use approved gas pipe and fittings; pressure test for leaks
  3. Electrical: 120V AC, 15 amp dedicated circuit required
  4. Venting: Properly size and install vent pipes according to installation manual
  5. Drain Lines: Install condensate drain with proper trap and routing

WARNING! Installation must be performed by qualified HVAC technician. Improper installation can cause fire, explosion, or carbon monoxide poisoning.

Initial Setup and Startup

After installation, perform initial setup and verification before regular operation.

  1. Gas Pressure Check: Verify inlet and manifold pressures are within specifications
  2. Vent Verification: Confirm proper draft and venting operation
  3. Electrical Check: Verify proper voltage and grounding
  4. Control Setup: Configure thermostat and furnace settings
  5. Test Sequence: Run complete heating cycle and monitor operation

CAUTION! Never bypass safety controls or operate furnace with access panels removed.

Technical Specifications

Controls and Operation

Integrated control board manages all furnace functions with LED status indicators.

Control Board Features: POWER ON/OFF switch, diagnostic LED, mode selection, fan control, temperature limits.

Operation Modes: HEAT, COOL (with AC), FAN ONLY. Temperature Settings: Adjust via compatible thermostat. Fan Control: AUTO or CONTINUOUS operation. Safety Monitoring: Continuous monitoring of flame, pressure, and temperature conditions.

Maintenance Procedures

Regular maintenance ensures optimal performance and extends furnace life.

  1. Monthly: Check and replace air filter if dirty
  2. Seasonal: Inspect burners, heat exchanger, and vent system
  3. Annual: Professional inspection and cleaning recommended
  4. Blower Maintenance: Clean blower wheel and motor annually
  5. Drain System: Clear condensate drain and trap monthly

Tip: Keep area around furnace clean and free of combustible materials.

Safety Features

Multiple safety systems protect against hazardous conditions.

Safety FeatureFunction
Flame Rollout SwitchDetects flame outside combustion chamber
High Limit SwitchPrevents overheating by shutting off burners
Pressure SwitchesVerify proper venting operation
Flame SensorConfirms burner ignition within safety time
Gas ValveAutomatic shutoff if ignition fails
Ignition ControlLimited trial-for-ignition period

Thermostat Configuration

Compatible with most 24V digital thermostats for precise temperature control.

  1. Wiring: Connect R, W, G, Y, C terminals as needed
  2. Programming: Set heating schedule and temperature preferences
  3. Fan Control: Configure AUTO or ON operation
  4. Temperature Differential: Adjust for comfort and efficiency
  5. System Mode: Select HEAT, COOL, or OFF

WARNING! Always turn off power before working on thermostat wiring.

Seasonal Maintenance

Prepare furnace for heating season and perform off-season maintenance.

Pre-Season Checklist: Replace filter, inspect vent system, test safety controls, verify thermostat operation. Off-Season: Clean furnace interior, cover if not in use, schedule professional service.

CAUTION! Never operate furnace without proper air filter installed.

Regulatory Compliance

UL certified for safety standards. ANSI Z21.47 compliant for gas-fired central furnaces. Meets DOE energy efficiency requirements. EPA compliant for emissions. For technical support, contact Gaffers and Sattler at 1-800-555-HEAT or visit www.gaffers-sattler.com.

Troubleshooting Guide

SymptomPossible CauseCorrective Action
Furnace won't startPower, thermostat, safety lockoutCheck power switch, thermostat settings, reset safety controls
No heatGas supply, ignition, filterVerify gas valve on, check for ignition, replace dirty filter
Short cyclingDirty filter, high limitReplace filter, check for restricted airflow
Blower not runningMotor, capacitor, controlCheck blower motor, capacitor, control board signals
Unusual noisesLoose parts, motor, ductworkTighten components, inspect blower, check duct connections

Reset Procedure: Turn power off for 30 seconds, then restore power.

Service: 1-800-555-HEAT; www.gaffers-sattler.com

Gaffers and Sattler U100 Furnace Manual © - All Rights Reserved 2025