Goodman Forced Air Furnace Manual

The Goodman Forced Air Furnace is a high-efficiency heating system designed for residential use, featuring variable-speed blower motors, electronic ignition systems, multiple heat exchanger stages, and integrated safety controls. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting Thermostat 7. Operating Procedures 8. Maintenance Schedule 9. Care & Cleaning 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Heat exchanger, blower assembly, gas valve, ignition system, pressure switches, limit switches, venting system.

FeatureDescription
Heat exchangerStainless steel primary and secondary heat exchangers
Blower motorVariable-speed ECM motor for efficient airflow
Gas valveElectronic modulating gas valve for precise control
Ignition systemHot surface ignition for reliable startup
Pressure switchesSafety switches to verify proper venting
Limit switchesHigh-temperature safety cutoffs
Control boardMicroprocessor-based control system
Venting systemPVC vent pipes for sidewall or roof termination
Filter systemStandard 1-inch or 4-inch media filter compatibility
Diagnostic lightsLED status indicators for troubleshooting

Installation

Unpack and inspect all components. Ensure proper clearances and location requirements.

  1. Position furnace: Place on level surface with proper clearances (typically 1" sides, 6" front, 24" top).
  2. Connect gas line: Use black iron pipe with proper thread sealant; pressure test for leaks.
  3. Install venting: Use approved PVC pipe with proper slope and termination clearances.
  4. Electrical connections: Connect 120V power supply and thermostat wiring.
  5. Ductwork: Connect supply and return ducts with proper sealing.

WARNING! Gas appliances require professional installation. Only qualified technicians should perform installation. Ensure proper combustion air and ventilation.

First-Time Setup

Complete installation verification and initial startup procedures.

  1. Gas pressure check: Verify inlet and manifold pressures per specifications.
  2. Venting verification: Confirm proper draft and vent pipe integrity.
  3. Electrical checks: Verify proper voltage and thermostat connections.
  4. Startup sequence: Turn on gas supply, power up furnace, set thermostat to heat mode.
  5. Performance verification: Check temperature rise, airflow, and combustion analysis.

CAUTION! Never bypass safety controls. Always verify proper operation before leaving installation.

Specifications

Controls and Settings

Integrated control board with diagnostic capabilities and user-adjustable settings.

Control Board: POWER switch, diagnostic LED lights, dip switch settings, terminal strip for thermostat connections.

Thermostat Settings: HEAT/COOL/OFF mode, temperature setpoint, fan AUTO/ON. Control Board DIP Switches: Heat staging, blower delays, accessory configuration. Diagnostic Lights: Flash codes for troubleshooting (1 flash = normal, multiple flashes = error codes).

Connecting Thermostat

Standard thermostat connections using 18-gauge low-voltage wiring.

  1. Turn off power to furnace before connecting thermostat wires.
  2. Connect wires to control board terminal strip: R (24V power), W (heat), G (fan), C (common).
  3. For multi-stage systems: Additional W2, Y1, Y2 terminals for second stage heating/cooling.
  4. Verify proper thermostat operation after power restoration.

Tip: Use color-coded thermostat wire for easy identification and proper connections.

Operating Procedures

Normal heating operation and seasonal startup/shutdown procedures.

  1. Seasonal startup: Turn on gas supply, restore electrical power, set thermostat to desired temperature.
  2. Normal operation: Furnace will cycle automatically based on thermostat demand.
  3. Fan operation: AUTO mode runs blower during heating cycles; ON mode provides continuous airflow.
  4. Seasonal shutdown: Turn off gas supply, turn off electrical power, close gas valve.
  5. Emergency shutdown: Turn off gas supply and electrical power immediately if unsafe condition detected.

WARNING! Never operate furnace without proper venting and combustion air. Carbon monoxide hazard exists if improperly installed or maintained.

Maintenance Schedule

Regular maintenance requirements for optimal performance and safety.

FrequencyMaintenance Task
MonthlyCheck and replace air filter if dirty
AnnuallyProfessional inspection and cleaning
AnnuallyCheck heat exchanger for cracks
AnnuallyClean burners and ignition system
AnnuallyVerify gas pressure and combustion
AnnuallyCheck vent system for obstructions
AnnuallyLubricate blower motor if required
AnnuallyCheck safety controls operation

Care & Cleaning

Turn off power before performing any cleaning. Use soft brush and vacuum for dust removal.

CAUTION! Never use water or liquid cleaners on electrical components. Keep combustion area clean and free of debris.

Regulatory Information

UL listed and ANSI certified for safety standards. Complies with ASHRAE 90.1 energy efficiency requirements. Manufactured to meet DOE energy conservation standards. For technical support, contact Goodman Manufacturing at 1-877-466-8626 or visit www.goodmanmfg.com.

Troubleshooting

SymptomPossible CauseCorrective Action
Furnace won't startPower, thermostat, safety switchCheck circuit breaker, thermostat settings, door switch
No heatGas supply, ignition, pressure switchVerify gas valve on, check for ignition failure, clear vent obstruction
Short cyclingDirty filter, high limitReplace air filter, check for restricted airflow
Blower won't runMotor, capacitor, control boardCheck for motor failure, replace capacitor, verify control signal
Gas odorGas leakImmediately shut off gas supply, evacuate area, call professional

Reset Procedure: Turn off power for 30 seconds, then restore power to reset control board.

Service: 1-877-466-8626; www.goodmanmfg.com