The Goodman GMSS92 is a high-efficiency gas furnace featuring multi-speed blower operation, electronic ignition, induced draft combustion system, and compatibility with various thermostat systems. This furnace is designed for residential installation with AFUE ratings up to 92%, suitable for single-family homes and multi-family applications. Below are key sections covering safety requirements, installation procedures, electrical connections, startup procedures, and maintenance guidelines.
Key components: Multi-speed ECM blower motor, hot surface ignitor, induced draft motor, pressure switches, flame sensor, and integrated control board.
| Feature | Description |
|---|---|
| AFUE Rating | Up to 92% efficiency |
| Blower Motor | Multi-speed ECM for optimal airflow |
| Ignition System | Hot surface electronic ignition |
| Combustion System | Induced draft with sealed combustion |
| Heat Exchanger | Stainless steel primary and secondary |
| Control Board | Integrated diagnostic LED system |
| Gas Valve | Multi-stage gas control |
| Pressure Switches | Dual pressure switch safety system |
| Filter System | Standard 1-inch or 4-inch media filter |
| Thermostat Compatibility | Single-stage and multi-stage capable |
Installation must comply with all local codes and national standards including NFPA 54, NFPA 70, and ANSI Z223.1.
WARNING! Failure to follow safety requirements may result in fire, explosion, property damage, personal injury, or death. Only qualified HVAC technicians should perform installation.
Proper installation location and clearances are critical for safe operation.
CAUTION! Never install furnace in areas where flammable vapors may be present.
All electrical connections must comply with NEC and local electrical codes.
Power Supply: 115V/60Hz dedicated circuit with proper grounding. Install disconnect switch within sight of furnace.
Thermostat: Use 18-gauge minimum thermostat wire. Connect R, W, G, C terminals for basic operation. For multi-stage systems, consult wiring diagram.
Proper venting is critical for safe operation and efficiency.
Tip: Always perform combustion analysis after installation to verify proper venting.
Gas piping must be properly sized and tested for leaks.
WARNING! Never use matches or open flames to check for gas leaks.
Complete startup procedure ensures safe and efficient operation.
CAUTION! Never bypass safety controls during startup testing.
Regular maintenance ensures optimal performance and longevity.
Replace air filters monthly during heating season. Clean blower assembly annually. Inspect heat exchanger for cracks during seasonal maintenance. Check condensate drain system for blockages. Verify flame sensor cleanliness.
CAUTION! Always disconnect power before performing maintenance.
Goodman GMSS92 furnace includes limited lifetime warranty on heat exchanger and 10-year limited warranty on functional parts. Warranty registration required within 60 days of installation. Professional installation required for warranty validation. For warranty claims, contact authorized Goodman dealer with proof of purchase and installation date.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Furnace won't start | Power supply/thermostat | Check disconnect switch; verify thermostat settings; check fuse. |
| No heat | Gas supply/ignition | Verify gas valve open; check for ignition lockout; inspect flame sensor. |
| Short cycling | Airflow/overheating | Check air filter; verify proper airflow; inspect limit switch. |
| Blower won't run | Motor/control board | Check blower capacitor; verify control board signals; test motor windings. |
| Condensate backup | Drain blockage | Clear condensate drain line; check trap; verify proper slope. |
Reset: Power cycle furnace to clear diagnostic codes.
Service: Contact authorized Goodman dealer for technical support.