The Goodman Furnace Installation Manual provides comprehensive guidance for proper installation, setup, and operation of Goodman gas and electric furnace systems. This manual covers safety precautions, technical specifications, installation procedures, wiring diagrams, startup instructions, maintenance requirements, and troubleshooting guidelines for various Goodman furnace models. Below are key sections for safe and efficient furnace installation and operation.
Critical safety information for furnace installation and operation.
| Hazard | Precaution |
|---|---|
| Gas leaks | Check all gas connections with soap solution; never use open flame |
| Electrical shock | Disconnect power before servicing; follow local electrical codes |
| Carbon monoxide | Ensure proper venting; install CO detectors in living areas |
| Fire hazard | Maintain clearance from combustibles; keep area clean |
| Burn risk | Allow furnace to cool before servicing; wear protective gear |
Essential preparations before furnace installation.
WARNING! Installation by unqualified personnel may result in property damage, personal injury, or death. Always hire licensed HVAC professionals.
Step-by-step furnace installation guide.
CAUTION! Never operate furnace without proper venting installed and verified.
Proper electrical installation and wiring guidelines.
Main Power: 115V AC, 15 Amp dedicated circuit with disconnect switch within sight of unit.
Thermostat Wiring: Standard 5-wire connection (R, C, W, G, Y) for single-stage systems; additional wires for multi-stage or communicating systems.
Grounding: Proper equipment grounding required per NEC. Polarity: Maintain correct hot and neutral connections. Fusing: Install correct size fuses or circuit breakers.
Venting system requirements and combustion air provisions.
Tip: Always perform combustion analysis after installation to verify proper operation.
Initial startup procedures and system verification.
WARNING! Never bypass safety controls or operate furnace with safety devices disabled.
Proper furnace operation and user controls.
Thermostat Settings: Program for energy efficiency. Filter Maintenance: Replace every 1-3 months. System Switch: ON for heating, OFF for service. Fan Switch: AUTO for automatic operation, ON for continuous circulation.
Recommended maintenance intervals and procedures.
Monthly: Check air filter; clean if dirty. Annually: Professional inspection and cleaning. Every 5 years: Heat exchanger inspection.
CAUTION! Always turn off power and gas supply before performing any maintenance.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No heat | Thermostat, power, gas valve | Check thermostat setting; verify power; check gas valve position |
| Furnace short cycles | Dirty filter, restricted vent | Replace filter; check vent system for obstructions |
| Blower runs continuously | Thermostat fan setting | Set thermostat fan to AUTO mode |
| Unusual noises | Loose components, airflow | Tighten access panels; check blower wheel; verify duct sizing |
| Lockout condition | Ignition failure, safety switch | Reset power; check flame sensor; verify pressure switches |
Reset Procedure: Turn thermostat to OFF, wait 5 minutes, turn to HEAT.
Service: Contact qualified HVAC technician for complex issues.
Goodman furnace warranty coverage and registration requirements.
Limited Lifetime Warranty: Heat exchanger. 10-Year Parts Limited Warranty: Covered components. 1-Year Labor Allowance: For registered products. To activate full warranty: Register within 60 days of installation at www.goodmanmfg.com or call 1-877-466-8626. Keep original receipt and installation date for warranty claims.