Goodman Gas Furnace Service Manual

The Goodman Gas Furnace is a high-efficiency heating system designed for residential use, featuring advanced combustion technology, multiple safety controls, and energy-efficient operation. This manual covers installation, operation, maintenance, troubleshooting, and safety procedures for certified HVAC technicians. Below are key sections for safety protocols, technical specifications, installation procedures, maintenance schedules, and troubleshooting guidelines.

1. Safety Information 2. Technical Specifications 3. Installation Procedures 4. System Components 5. Operation Instructions 6. Maintenance Schedule 7. Electrical Wiring 8. Gas Connections 9. Venting Requirements 10. Error Codes 11. Troubleshooting Guide

Safety Information

Critical safety protocols for handling and servicing Goodman gas furnaces.

Hazard TypeSafety Precautions
Gas LeaksUse leak detection solution; never use open flame to check for leaks
Electrical ShockDisconnect power before servicing; use lockout/tagout procedures
Carbon MonoxideEnsure proper venting; install CO detectors in living areas
High TemperaturesAllow system to cool before handling combustion components
Moving PartsKeep hands clear of blower wheel and inducer motor during operation

Technical Specifications

Detailed technical data for Goodman gas furnace models.

Installation Procedures

Step-by-step installation guidelines for certified technicians.

  1. Location Selection: Install in dry, clean area with adequate combustion air and service clearance
  2. Combustion Air: Ensure proper fresh air intake according to local codes
  3. Venting: Install PVC vent pipes with proper slope and termination clearances
  4. Gas Connection: Use approved pipe compound; pressure test at 14" WC for 10 minutes
  5. Electrical: Connect to dedicated 15A circuit; install disconnect switch within sight
  6. Ductwork: Seal all connections; ensure proper airflow and static pressure
  7. Startup: Perform complete startup sequence and combustion analysis

WARNING! Installation must comply with all local codes and manufacturer specifications. Only qualified technicians should perform installation.

System Components

Major components and their functions in Goodman gas furnace systems.

ComponentFunction
Heat ExchangerTransfers heat from combustion gases to air stream
Gas ValveRegulates gas flow to burners; includes safety shutoff
Inducer MotorCreates draft for combustion and venting
Blower MotorCirculates air through heat exchanger and ductwork
Ignition SystemHot surface igniter or intermittent pilot ignition
Control BoardMonitors safety devices and controls system operation
Flame SensorDetects burner flame; shuts off gas if no flame
Pressure SwitchesVerify proper venting and inducer operation

Operation Instructions

Proper operation procedures and control settings.

  1. Thermostat Settings: Set to HEAT mode with desired temperature
  2. System Sequence: Inducer motor starts, pressure switch closes, igniter heats, gas valve opens
  3. Blower Operation: Blower starts after heat exchanger warm-up delay
  4. Cycle Completion: Gas valve closes when thermostat satisfied, blower runs for post-purge
  5. Continuous Fan: Use FAN ON setting for continuous air circulation

Note: System includes built-in delays to ensure proper operation and safety.

Maintenance Schedule

Recommended maintenance intervals and procedures.

Maintenance TaskFrequencyProcedure
Air Filter ReplacementMonthly during heating seasonInstall clean filter with arrow pointing toward blower
Blower CleaningAnnuallyVacuum blower assembly and motor
Heat Exchanger InspectionAnnuallyVisual inspection for cracks or corrosion
Burner CleaningAnnuallyClean burners and inspect flame pattern
Vent System InspectionAnnuallyCheck for obstructions and proper slope
Gas Pressure CheckAnnuallyVerify manifold pressure and adjust if needed

Electrical Wiring

Electrical connections and control circuit diagrams.

  1. Power Supply: 120V AC connection to control board L1 and L2 terminals
  2. Thermostat Wiring: Connect R, W, G, C terminals per wiring diagram
  3. Safety Devices: Series connection of limit switches, rollout switches, pressure switches
  4. Motor Speeds: Blower motor has multiple speed taps for heating/cooling/continuous fan
  5. Diagnostic LED: Control board LED flashes error codes for troubleshooting

CAUTION! Always disconnect power before servicing electrical components.

Gas Connections

Gas line installation and pressure adjustment procedures.

  1. Pipe Sizing: Use adequate pipe size based on length and BTU input
  2. Shutoff Valve: Install manual gas shutoff valve within 6 feet of unit
  3. Drip Leg: Install sediment trap before gas connection
  4. Pressure Test: Test gas lines at 14" WC for 10 minutes with no pressure drop
  5. Manifold Pressure: Adjust gas valve to specified manifold pressure (typically 3.5" WC natural gas)
  6. Combustion Analysis: Verify CO2 levels and temperature rise within specifications

Venting Requirements

PVC vent pipe installation guidelines and clearances.

Error Codes

Control board LED flash codes for diagnostic purposes.

Flash PatternError DescriptionPossible Causes
1 FlashPressure Switch ErrorBlocked vent, inducer failure, switch malfunction
2 FlashesIgnition FailureGas supply, igniter, flame sensor, gas valve
3 FlashesLimit Switch LockoutRestricted airflow, dirty filter, blower issues
4 FlashesFlame Loss ErrorFlame sensor, gas pressure, grounding issues
5 FlashesRollout Switch TripBlocked heat exchanger, improper combustion
ContinuousNormal OperationSystem operating properly

Troubleshooting Guide

Common service issues and corrective actions.

SymptomPossible CauseCorrective Action
No HeatThermostat, power, gas supplyCheck thermostat setting, circuit breaker, gas valve
Short CyclingDirty filter, airflow restrictionReplace filter, check ductwork, verify static pressure
Blower Not RunningMotor, capacitor, control boardCheck voltage to motor, test capacitor, verify control signals
Unusual NoisesLoose components, airflow issuesTighten mounting hardware, check for obstructions
Pilot/Igniter FailureIgniter, flame sensor, gas valveTest igniter continuity, clean flame sensor, check gas pressure
High CO ReadingsCombustion issues, heat exchangerAdjust air shutter, check for cracks in heat exchanger

Reset Procedure: Power cycle unit to clear lockout conditions.

Technical Support: 1-877-254-4729; www.goodmanmfg.com